Search results

  1. Results from the WOW.Com Content Network
  2. Cross-linked polyethylene - Wikipedia

    en.wikipedia.org/wiki/Cross-linked_polyethylene

    A cross-linked polyethylene (PEX) pipe. Cross-linked polyethylene, commonly abbreviated PEX, XPE or XLPE, is a form of polyethylene with cross-links.It is used predominantly in building services pipework systems, hydronic radiant heating and cooling systems, domestic water piping, insulation for high tension (high voltage) electrical cables, and baby play mats.

  3. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    The test is typically performed over a range of test voltages from 0.5 Uo to 2 Uo depending on the standard/guide that is being followed. Apply VLF in order to detect and measure partial discharge . In this case, the IEEE 400.3 outlines a procedure for assessment and IEC 60270 provides the background for partial discharge testing of high ...

  4. Cable fault location - Wikipedia

    en.wikipedia.org/wiki/Cable_fault_location

    Murray loop test employs the principle of wheatstone bridge for locating the fault. To perform this test, it is necessary to have a sound cable running alongside the faulty cable. One end of the faulted cable is connected through a pair of resistors to the voltage source. Also a null detector is connected. The other end of the cable is shorted.

  5. High-voltage cable - Wikipedia

    en.wikipedia.org/wiki/High-voltage_cable

    High voltage is defined as any voltage over 1000 volts. [3] Those of 2 to 33 kV are usually called medium voltage cables, those over 50 kV high voltage cables.. Modern HV cables have a simple design consisting of a few parts: the conductor, the conductor shield, the insulation, the insulation shield, the metallic shield, and the jacket.

  6. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    Prior to 2013 IS 201-4:2001 ( I.S. 201 part 4: PVC and Low Smoke Halogen Free Sheathed cables for fixed wiring) permitted both the UK style of twin and earth, and also a version with a CPC with a cross-section equal to that of the main conductors and insulated in green and yellow inside the full length of the cable.

  7. Mineral-insulated copper-clad cable - Wikipedia

    en.wikipedia.org/wiki/Mineral-insulated_copper...

    PVC-sheathed MICC cable. Conductor cross section area is 1.5 mm 2; overall diameter is 7.2 mm. Mineral-insulated cables at a panel board. Mineral-insulated copper-clad cable is a variety of electrical cable made from copper conductors inside a copper sheath, insulated by inorganic magnesium oxide powder.

  8. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60172 Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires; IEC 60183 Guidance for the selection of high-voltage A.C. cable systems; IEC 60188 High-pressure mercury vapour lamps – Performance specifications; IEC 60189 Low-frequency cables and wires with PVC insulation and PVC sheath

  9. Test method - Wikipedia

    en.wikipedia.org/wiki/Test_method

    A test method is a method for a test in science or engineering, such as a physical test, chemical test, or statistical test. It is a definitive procedure that produces a test result. [ 1 ] In order to ensure accurate and relevant test results, a test method should be "explicit, unambiguous, and experimentally feasible.", [ 2 ] as well as ...