The NFPA 72 "covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire warning equipment and emergency communications systems (ECS), and their components."
The standard fire alarm sound used in most of North America. Coding refers to the pattern or tones a notification appliance sounds in and is controlled either by the panel or by setting jumpers or DIP switches on the notification appliances. The majority of audible notification appliances installed prior to 1996 produced a steady sound for ...
New codes and standards introduced around 2010, especially the new UL Standard 2572, the US Department of Defense's UFC 4-021-01 Design and O&M Mass Notification Systems, and NFPA 72 2010 edition Chapter 24, have led fire alarm system manufacturers to expand their systems voice evacuation capabilities to support new requirements for mass ...
The alarm transmission methods covered under UL 365 can be categorized under standard line security or encrypted line security. The systems are required to operate within the limits of Class 2 remote control and signal circuits as defined by the National Electrical Code, NFPA 70. [15]
Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...
Many modern fire alarm pull stations are single-action and only require the user to pull down a handle to sound the alarm. Other fire alarm pull stations are dual-action, and as such require the user to perform a second task before pulling down, such as lifting or pushing in a panel on the station or breaking a glass panel with an attached hammer.
The publication Life Safety Code, known as NFPA 101, is a consensus standard widely adopted in the United States. [according to whom?] It is administered, trademarked, copyrighted, and published by the National Fire Protection Association and, like many NFPA documents, is systematically revised on a three-year cycle.
Sparky the Fire Dog. Sparky the Fire Dog is the official mascot of the National Fire Protection Association. Created in 1951 to promote fire safety education for children, [9] [10] he is a Dalmatian dressed in firefighting gear. A children's book about Sparky by Don Hoffman was published in 2011.