enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Detection limit - Wikipedia

    en.wikipedia.org/wiki/Detection_limit

    In analytical chemistry, the detection limit, lower limit of detection, also termed LOD for limit of detection or analytical sensitivity (not to be confused with statistical sensitivity), is the lowest quantity of a substance that can be distinguished from the absence of that substance (a blank value) with a stated confidence level (generally 99%).

  3. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  4. Blank value - Wikipedia

    en.wikipedia.org/wiki/Blank_value

    These contribute to the sample value in the analytical measurement and therefore have to be subtracted. [ 1 ] The limit of blank is defined by the Clinical And Laboratory Standards Institute as the highest apparent analyte concentration expected to be found when replicates of a sample containing no analyte are tested.

  5. Analytical quality control - Wikipedia

    en.wikipedia.org/wiki/Analytical_quality_control

    Validation of analytical procedures is imperative in demonstrating that a drug substance is suitable for a particular purpose. [5] Common validation characteristics include: accuracy, precision (repeatability and intermediate precision), specificity, detection limit, quantitation limit, linearity, range, and robustness.

  6. Odor detection threshold - Wikipedia

    en.wikipedia.org/wiki/Odor_detection_threshold

    The odor detection threshold is the lowest concentration of a certain odor compound that is perceivable by the human sense of smell. The threshold of a chemical compound is determined in part by its shape, polarity, partial charges, and molecular mass. The olfactory mechanisms responsible for a compound's different detection threshold is not ...

  7. Chemiluminescence - Wikipedia

    en.wikipedia.org/wiki/Chemiluminescence

    A typical example is NO determination with detection limits down to 1 ppb. Highly specialised chemiluminescence detectors have been used recently to determine concentrations as well as fluxes of NO x with detection limits as low as 5 ppt. [14] [15] [16] Analysis of inorganic species in liquid phase

  8. Laboratory quality control - Wikipedia

    en.wikipedia.org/wiki/Laboratory_quality_control

    An example of a Levey–Jennings chart with upper and lower limits of one and two times the standard deviation. A Levey–Jennings chart is a graph that quality control data is plotted on to give a visual indication whether a laboratory test is working well. The distance from the mean is measured in standard deviations.

  9. Miniature mass spectrometer - Wikipedia

    en.wikipedia.org/wiki/Miniature_mass_spectrometer

    The MMS can reach a detection limit close to 10 ppm, a dynamic range of 5 orders of magnitude and a mass range up to 103 Da. The mass analyzer overall sizes 3.5cmx6cmx7.5 cm and it weighs 0.8 kg and consumes 2.5 W. [11]