enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. MRI pulse sequence - Wikipedia

    en.wikipedia.org/wiki/MRI_pulse_sequence

    An MRI pulse sequence in magnetic resonance imaging (MRI) is a particular setting of pulse sequences and pulsed field gradients, resulting in a particular image appearance. [ 1 ] A multiparametric MRI is a combination of two or more sequences, and/or including other specialized MRI configurations such as spectroscopy .

  3. Template:Table of MRI sequences - Wikipedia

    en.wikipedia.org/.../Template:Table_of_MRI_sequences

    High signal for paramagnetic substances, such as MRI contrast agents [2] Standard foundation and comparison for other sequences T2 weighted: T2: Measuring spin–spin relaxation by using long TR and TE times Higher signal for more water content [1] Low signal for fat in standard Spine Echo (SE), [1] though not with Fast Spin Echo/Turbo Spin ...

  4. Physics of magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Physics_of_magnetic...

    Modern 3 Tesla clinical MRI scanner.. Magnetic resonance imaging (MRI) is a medical imaging technique mostly used in radiology and nuclear medicine in order to investigate the anatomy and physiology of the body, and to detect pathologies including tumors, inflammation, neurological conditions such as stroke, disorders of muscles and joints, and abnormalities in the heart and blood vessels ...

  5. Shinnar–Le Roux algorithm - Wikipedia

    en.wikipedia.org/wiki/Shinnar–Le_Roux_algorithm

    Given a desired magnetization profile, determining the RF pulse that produces it is generally nonlinear, due to the non-linearity of the Bloch equations. At low tip angles, the RF excitation waveform can be approximated by the inverse Fourier Transform of the desired frequency profile, using the excitation kspace analysis.

  6. Fast low angle shot magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Fast_low_angle_shot...

    The generic FLASH technique emerges as a gradient echo sequence which combines a low-flip angle radio-frequency excitation of the NMR signal (recorded as a spatially encoded gradient echo) with a rapid repetition of the basic sequence. The repetition time is usually much shorter than the typical T1 relaxation time of the protons in biologic ...

  7. Functional magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Functional_magnetic...

    Thus MR pulse sequences sensitive to T 2 * show more MR signal where blood is highly oxygenated and less where it is not. This effect increases with the square of the strength of the magnetic field. The fMRI signal hence needs both a strong magnetic field (1.5 T or higher) and a pulse sequence such as EPI, which is sensitive to T 2 * contrast. [23]

  8. Pulse sequence - Wikipedia

    en.wikipedia.org/wiki/Pulse_sequence

    The thin bar denotes a 90° pulse, while the thick bar denotes a 180° pulse. INEPT is a common building block of NMR experiments to improve 15 N signal. [1] In Fourier transform NMR spectroscopy and imaging, a pulse sequence describes a series of radio frequency pulses applied to the sample, such that the free induction decay is related

  9. Inversion recovery - Wikipedia

    en.wikipedia.org/wiki/Inversion_recovery

    Fluid-attenuated inversion recovery (FLAIR) [2] is an inversion-recovery pulse sequence used to nullify the signal from fluids. For example, it can be used in brain imaging to suppress cerebrospinal fluid so as to bring out periventricular hyperintense lesions, such as multiple sclerosis plaques.