enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Steady-state free precession imaging - Wikipedia

    en.wikipedia.org/wiki/Steady-state_free...

    Steady-state free precession (SSFP) imaging is a magnetic resonance imaging (MRI) sequence which uses steady states of magnetizations. In general, SSFP MRI sequences are based on a (low flip angle) gradient echo MRI sequence with a short repetition time which in its generic form has been described as the FLASH MRI technique. While spoiled ...

  3. Athinoula A. Martinos Center for Biomedical Imaging - Wikipedia

    en.wikipedia.org/wiki/Athinoula_A._Martinos...

    At the MGH Navy Yard site, there are eight large bore and five small bore MRI scanning bays used primarily for research, [2] including the high-gradient field Human Connectome Project scanner, a 7 Tesla magnet for human radiography, and a combined PET-MRI. The Martinos Center also served as the site for the development of magnetoencephalography ...

  4. Fast low angle shot magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Fast_low_angle_shot...

    Fast low angle shot magnetic resonance imaging (FLASH MRI) is a particular sequence of magnetic resonance imaging. It is a gradient echo sequence which combines a low-flip angle radio-frequency excitation of the nuclear magnetic resonance signal (recorded as a spatially encoded gradient echo) with a short repetition time .

  5. Aqueductal stenosis - Wikipedia

    en.wikipedia.org/wiki/Aqueductal_stenosis

    When constructive interference in steady state (CISS) or fast imaging employing steady-state acquisition (FIESTA) sequence are used, subtle abnormalities or partial obstructions in the aqueduct can be depicted in the MRI. [1] For example, CISS can be used to determine if a thin membrane interfering with CSF flow is present. [10]

  6. Magnetic resonance angiography - Wikipedia

    en.wikipedia.org/wiki/Magnetic_resonance_angiography

    Magnetic resonance angiography (MRA) is a group of techniques based on magnetic resonance imaging (MRI) to image blood vessels. Magnetic resonance angiography is used to generate images of arteries (and less commonly veins) in order to evaluate them for stenosis (abnormal narrowing), occlusions, aneurysms (vessel wall dilatations, at risk of rupture) or other abnormalities.

  7. Template:Table of MRI sequences - Wikipedia

    en.wikipedia.org/.../Template:Table_of_MRI_sequences

    High signal for paramagnetic substances, such as MRI contrast agents [2] Standard foundation and comparison for other sequences T2 weighted: T2: Measuring spin–spin relaxation by using long TR and TE times Higher signal for more water content [1] Low signal for fat in standard Spine Echo (SE), [1] though not with Fast Spin Echo/Turbo Spin ...

  8. Blood-oxygen-level-dependent imaging - Wikipedia

    en.wikipedia.org/wiki/Blood-oxygen-level...

    In Ogawa's experiments, blood-oxygen-level-dependent imaging of rodent brain slice contrast in different components of the air. At high magnetic fields, water proton magnetic resonance images of brains of live mice and rats under anesthetization have been measured by a gradient echo pulse sequence.

  9. Real-time MRI - Wikipedia

    en.wikipedia.org/wiki/Real-time_MRI

    A study performed by Laubrock et al. [28] demonstrated that RT-MRI produced higher quality images with a higher SNR than cine CMR with a bSSFP sequence and radial k-space sampling. RT-MRI also removes the need for breath-holding while imaging, leading to a more comfortable experience for the patient as well.