Dynamic frequency scaling (also known as CPU throttling) is a power management technique in computer architecture whereby the frequency of a microprocessor can be automatically adjusted "on the fly" depending on the actual needs, to conserve power and reduce the amount of heat generated by the chip.
Thermal Monitor 2 (TM2) is a throttling control method used on LGA 775 versions of the Core 2, Pentium Dual-Core, Pentium D, Pentium 4 and Celeron processors and also on the Pentium M series of processors. [1] TM2 reduces processor temperature by lowering the CPU clock multiplier, and thereby the processor core speed. [2]
Processor manufacturers usually release two power consumption numbers for a CPU: typical thermal power, which is measured under normal load (for instance, AMD's average CPU power) maximum thermal power, which is measured under a worst-case load; For example, the Pentium 4 2.8 GHz has a 68.4 W typical thermal power and 85 W maximum thermal power.
This is generally known as Thermal Throttling in the case of reduction of clock speeds, or Thermal Shutdown in the case of a complete shutdown of the device or system. Cooling may be designed to reduce the ambient temperature within the case of a computer, such as by exhausting hot air, or to cool a single component or small area (spot cooling).
Thermal Design Power (TDP), also known as thermal design point, is the maximum amount of heat that a computer component (like a CPU, GPU or system on a chip) can generate and that its cooling system is designed to dissipate during normal operation at a non-turbo clock rate (base frequency).
Thermal simulations give engineers a visual representation of the temperature and airflow inside the equipment. Thermal simulations enable engineers to design the cooling system; to optimise a design to reduce power consumption, weight and cost; and to verify the thermal design to ensure there are no issues when the equipment is built.
Sketch of a heat sink with equivalent thermal resistances Thermal resistance and heat transfer coefficient plotted against flow rate for the specific heat sink design used in. [24] The data was generated using the equations provided in the article. The data shows that for an increasing air flow rate, the thermal resistance of the heat sink ...