ANSI/ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy is an American National Standard published by ASHRAE that establishes the ranges of indoor environmental conditions to achieve acceptable thermal comfort for occupants of buildings. It was first published in 1966, and since 2004 has been updated every three to six years.
The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.
ASHRAE 55-2017 defines the Cooling Effect (CE) at elevated air speed (above 0.2 metres per second (0.66 ft/s)) as the value that, when subtracted from both the air temperature and the mean radiant temperature, yields the same SET value under still air (0.1 m/s) as in the first SET calculation under elevated air speed. [1]
Sol-air temperature (T sol-air) is a variable used to calculate cooling load of a building and determine the total heat gain through exterior surfaces. It is an improvement over: It is an improvement over:
A Assuming an altitude of 194 metres above mean sea level (the worldwide median altitude of human habitation), an indoor temperature of 23 °C, a dewpoint of 9 °C (40.85% relative humidity), and 760 mmHg sea level–corrected barometric pressure (molar water vapor content = 1.16%).
The ASHRAE Handbook is the four-volume flagship publication of the nonprofit technical organization ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers [a]). This Handbook is considered the most comprehensive and authoritative repository of practical knowledge on the various topics that form the field of heating ...
Row 3. Values of the five parameters for the first C p equation; temperature limit for the equation. Row 4. Values of the five parameters for the second C p equation; temperature limit for the equation. Row 5. Values of the five parameters for the third C p equation; temperature limit for the equation. Row 6. Number of H T - H 298 equations ...
The operative temperature, which is a more functional measure of thermal comfort in a building, is calculated from air temperature, mean radiant temperature and air speed. [6] Maintaining a balance between the operative temperature and the mean radiant temperature can create a more comfortable space. [ 7 ]