enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Noise calculation - Wikipedia

    en.wikipedia.org/wiki/Noise_calculation

    Noise experts and some small specialized companies have slowly developed a limited number of calculation tools, which have increased in number and become more user-friendly, covering more application cases, and adding service elements to the noise calculation tools. The noise calculation process is complex in input (gathering data, correctly ...

  3. Noise floor - Wikipedia

    en.wikipedia.org/wiki/Noise_floor

    The noise floor limits the smallest measurement that can be taken with certainty since any measured amplitude can on average be no less than the noise floor. A common way to lower the noise floor in electronics systems is to cool the system to reduce thermal noise, when this is the major noise source. In special circumstances, the noise floor ...

  4. Friis formulas for noise - Wikipedia

    en.wikipedia.org/wiki/Friis_formulas_for_noise

    Friis formula or Friis's formula (sometimes Friis' formula), named after Danish-American electrical engineer Harald T. Friis, is either of two formulas used in telecommunications engineering to calculate the signal-to-noise ratio of a multistage amplifier. One relates to noise factor while the other relates to noise temperature.

  5. Noise reduction coefficient - Wikipedia

    en.wikipedia.org/wiki/Noise_reduction_coefficient

    The noise reduction coefficient (commonly abbreviated NRC) is a single number value ranging from 0.0 to 1.0 that describes the average sound absorption performance of a material. An NRC of 0.0 indicates the object does not attenuate mid-frequency sounds, but rather reflects sound energy.

  6. Signal-to-noise ratio - Wikipedia

    en.wikipedia.org/wiki/Signal-to-noise_ratio

    In the above formula, P is measured in units of power, such as watts (W) or milliwatts (mW), and the signal-to-noise ratio is a pure number. However, when the signal and noise are measured in volts (V) or amperes (A), which are measures of amplitude, [note 1] they must first be squared to obtain a quantity proportional to power, as shown below:

  7. Sound transmission class - Wikipedia

    en.wikipedia.org/wiki/Sound_transmission_class

    In the US, it is widely used to rate interior partitions, ceilings, floors, doors, windows and exterior wall configurations. Outside the US, the ISO Sound Reduction Index (SRI) is used. The STC rating very roughly reflects the decibel reduction of noise that a partition can provide. The STC is useful for evaluating annoyance due to speech ...

  8. Sabin (unit) - Wikipedia

    en.wikipedia.org/wiki/Sabin_(unit)

    The unit was renamed the sabin after Sabine, and it is now defined as "the absorption due to unit area of a totally absorbent surface". [1] Sabins may be calculated with either imperial or metric units. One square foot of 100% absorbing material has a value of one imperial sabin, and 1 square metre of 100% absorbing material has a value of one ...

  9. Noise temperature - Wikipedia

    en.wikipedia.org/wiki/Noise_temperature

    The noise factor (a linear term) is more often expressed as the noise figure (in decibels) using the conversion: = ⁡ The noise figure can also be seen as the decrease in signal-to-noise ratio (SNR) caused by passing a signal through a system if the original signal had a noise temperature of 290 K. This is a common way of expressing the noise ...