enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Implantable cardioverter-defibrillator - Wikipedia

    en.wikipedia.org/wiki/Implantable_cardioverter...

    A normal chest X-ray after placement of an ICD, showing the ICD generator in the upper left chest and the ICD lead in the right ventricle of the heart. Note the 2 opaque coils along the ICD lead. The process of implantation of an ICD system is similar to implantation of an artificial pacemaker. In fact, ICDs are composed of an ICD generator and ...

  3. Wearable cardioverter defibrillator - Wikipedia

    en.wikipedia.org/wiki/Wearable_cardioverter...

    A WCD is also a temporary therapeutic option in case an implantable cardioverter defibrillator (ICD) cannot be implanted immediately. The WCD enables patients to continue their normal life without constantly worrying about their risk for SCD. The WCD is a non-invasive medical device.

  4. Transcatheter aortic valve replacement - Wikipedia

    en.wikipedia.org/wiki/Transcatheter_aortic_valve...

    The first implantation in a human was performed on 16 April 2002 by Alain Cribier in Hopital Charles Nicolle, at the University of Rouen, France. [30] Technology experts Stan Rowe and Stan Rabinowitz partnered with physicians Alain Cribier and Martin Leon of NewYork–Presbyterian Hospital and others to create the company Percutaneous Valve ...

  5. Hypertrophic cardiomyopathy - Wikipedia

    en.wikipedia.org/wiki/Hypertrophic_cardiomyopathy

    For people with HCM who exhibit one or more of the major risk factors for sudden cardiac death, an implantable cardioverter-defibrillator (ICD) or a combination pacemaker/ICD all-in-one unit may be recommended as an appropriate precaution. [7] [20] [63] [64] In 2014, European Society of Cardiology suggested a practical risk score to calculate ...

  6. Aortic valve replacement - Wikipedia

    en.wikipedia.org/wiki/Aortic_valve_replacement

    Their durability is long life, while tissue valves can last for up to 15–20 years. [ 26 ] [ 27 ] [ 13 ] Since the risk of blood clots forming is higher with mechanical valves than with tissue valves, patients with mechanical heart valves are required to take anticoagulant (blood-thinning) drugs, such as warfarin , long-life, making them more ...

  7. Life expectancy in the US is forecast to grow slightly, but ...

    www.aol.com/news/life-expectancy-us-forecast...

    Life expectancy in the U.S. is projected to increase from 78.3 years in 2022 to 79.9 years in 2035 and to 80.4 years in 2050 for all sexes combined, researchers said.

  8. Subcutaneous implantable defibrillator - Wikipedia

    en.wikipedia.org/wiki/Subcutaneous_implantable...

    Subcutaneous implantable cardioverter defibrillator, or S-ICD, is an implantable medical device for detecting and terminating ventricular tachycardia and ventricular fibrillation in patients at risk of sudden cardiac arrest. [1]

  9. 2,500-year-old shipwreck and anchors discovered off coast of ...

    www.aol.com/news/2-500-old-shipwreck-anchors...

    A shipwreck dating back to the 5th and 6th centuries B.C. was discovered earlier this year off the coast of Sicily, Italian officials said.