Search results
Results from the WOW.Com Content Network
All HVAC systems have an intake, air filter, and air conditioning liquid. However, when designing HVAC systems, many engineers design it for a specific setting and/or purpose. When engineers are designing an HVAC system, they try their best to make it compact while still being able to perform at the highest level and experiment with different ...
Diagram of air movement in an underfloor air distribution system. Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system.
A set of wiring diagrams may be required by the electrical inspection authority to approve connection of the residence to the public electrical supply system. Wiring diagrams will also include panel schedules for circuit breaker panelboards, and riser diagrams for special services such as fire alarm or closed-circuit television or other special ...
The schematic is a line diagram, not necessarily to scale, that describes interconnection of components in a system. The main features of a schematic drawing show: A two dimensional layout with divisions that show distribution of the system between building levels, or an isometric-style layout that shows distribution of systems across ...
DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...
These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.
Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.
All metallic systems in a building are to be bonded to the building grounding system, such as water, natural gas, HVAC piping, and others. Larger wires are generally furnished only in black; these black wires may be properly re-identified with suitable paint or tape.