  2. Variable refrigerant flow - Wikipedia

    en.wikipedia.org/wiki/Variable_refrigerant_flow

    Variable refrigerant flow (VRF), also known as variable refrigerant volume (VRV), is an HVAC technology invented by Daikin Industries, Ltd. in 1982. [1] Similar to ductless mini-split systems, VRFs use refrigerant as the primary cooling and heating medium, and are usually less complex than conventional chiller-based systems.

  3. Air conditioning - Wikipedia

    en.wikipedia.org/wiki/Air_conditioning

    Buildings designed with passive air conditioning are generally less expensive to construct and maintain than buildings with conventional HVAC systems with lower energy demands. [112] While tens of air changes per hour, and cooling of tens of degrees, can be achieved with passive methods, site-specific microclimate must be taken into account ...

  4. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    All HVAC systems have an intake, air filter, and air conditioning liquid. However, when designing HVAC systems, many engineers design it for a specific setting and/or purpose. When engineers are designing an HVAC system, they try their best to make it compact while still being able to perform at the highest level and experiment with different ...

  5. Heat pump - Wikipedia

    en.wikipedia.org/wiki/Heat_pump

    For example, an air-to-water heat pump that produces 6kW at a SCOP of 4.62 will give over 4kW of energy into a heating system for every kilowatt of energy that the heat pump uses itself to operate. When used for space heating, heat pumps are typically more energy-efficient than electric resistance and other heaters.

  6. Mechanical systems drawing - Wikipedia

    en.wikipedia.org/wiki/Mechanical_systems_drawing

    The schematic is a line diagram, not necessarily to scale, that describes interconnection of components in a system. The main features of a schematic drawing show: A two dimensional layout with divisions that show distribution of the system between building levels, or an isometric-style layout that shows distribution of systems across ...

  7. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Split systems are preferred and widely used worldwide except in North America. In North America, split systems are most often seen in residential applications, but they are gaining popularity in small commercial buildings. Split systems are used where ductwork is not feasible or where the space conditioning efficiency is of prime concern. [33]

  8. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    FCUs are commonly used in HVAC systems of residential, commercial, and industrial buildings that use ducted split air conditioning or central plant cooling. FCUs are typically connected to ductwork and a thermostat to regulate the temperature of one or more spaces and to assist the main air handling unit for each space if used with chillers.

  9. Air source heat pump - Wikipedia

    en.wikipedia.org/wiki/Air_source_heat_pump

    The main components of a split-system (called split as there are both inside and outside coils) air source heat pump are: An outdoor evaporator heat exchanger coil, which extracts heat from ambient air; One or more [9] indoor condenser heat exchanger coils. They transfer the heat into the indoor air, or an indoor heating system such as water ...