Air flow in fume hood demonstrated by dry ice fog. A fume hood is typically a large piece of equipment enclosing six sides of a work area (including a movable sash window or door), the bottom of which is most commonly located at a standing work height (at least 28 to 34 inches (71 to 86 cm) above the floor).
The majority of guidance available for design of heat and smoke building vents installed in buildings is restricted to nonsprinklered, single-story buildings. [4] This is partly a historical consequence of the installation of heat and smoke vents following the August 1953 General Motors, Livonia, MI major fire in a nonsprinklered manufacturing facility which effectively stopped the production ...
Fume hoods were introduced about 100 years ago to safeguard personnel working with hazardous materials. While many changes and improvements have been made, the basic concept and design of fume hoods remains the same. Air is drawn from the workplace, around the worker and into the front of the hood, and is then exhausted out of the laboratory.
A fume hood is an example of an engineering control that uses local exhaust ventilation combined with an enclosure to isolate a worker from nanomaterials that may become airborne. Engineering controls for nanomaterials are a set of hazard control methods and equipment for workers who interact with nanomaterials .
A kitchen hood in a small apartment. A kitchen hood, exhaust hood, hood fan, extractor hood, or range hood is a device containing a mechanical fan that hangs above the stove or cooktop in the kitchen. It removes airborne grease, combustion products, fumes, smoke, heat, and steam from the air by evacuation of the air and filtration. [1]
In kitchen ventilation systems, or for laboratory fume hoods, the design of effective effluent capture can be more important than the bulk amount of ventilation in a space. More generally, the way that an air distribution system causes ventilation to flow into and out of a space impacts the ability of a particular ventilation rate to remove ...
Despite their similar appearance, a laminar flow cabinet should not to be confused with a fume hood. A laminar flow cabinet blows unfiltered exhaust air towards the worker and is not safe for work with pathogenic agents, [ 2 ] : 13 [ 3 ] while a fume hood maintains negative pressure with constant exhaust to protect the user, but does not ...
A fume hood is an example of an engineering control that uses local exhaust ventilation combined with an enclosure to isolate a worker from airborne gasses or particulates. Ventilation systems are distinguished as being either local or general.