enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. ASHRAE 90.1 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_90.1

    ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...

  3. United States building energy codes - Wikipedia

    en.wikipedia.org/wiki/United_States_building...

    [2] [5] [6] [4] The primary baseline national model energy codes are the International Energy Conservation Code (IECC), the ANSI/ASHRAE/IESNA Standard 90.1: Energy-Efficient Standard for Buildings Except Low-Rise Residential Buildings (ASHRAE 90.1), and ASHRAE Standard 90.2: Energy-Efficient Standard of New Low-Rise Residential Buildings.

  4. Low-flow fixtures - Wikipedia

    en.wikipedia.org/wiki/Low-flow_fixtures

    Kitchen and bathroom faucets were limited to a flow rate of 2.2 gpm (gallons per minute) at 60 psi, and residential shower heads were limited to a flowrate of 2.5 gpm at 80 psi. [ 3 ] In response to an increasing number of water shortages and increased water utility rates there has been recent legislation by many states leading the way in water ...

  5. ASHRAE - Wikipedia

    en.wikipedia.org/wiki/ASHRAE

    ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]

  6. Lighting power density - Wikipedia

    en.wikipedia.org/wiki/Lighting_power_density

    Space By Space Method. A defined list of many possible space types within a building the associated watts per square foot allowance. For example, ANSI/ASHRAE/IESNA Standard 90.1-2007 allows the Emergency Space of a hospital to be designed for 2.7 watts per square foot, but the Recovery areas of a hospital would be allowed 0.8 watts per square foot.

  7. Moisture removal efficiency - Wikipedia

    en.wikipedia.org/wiki/Moisture_removal_efficiency

    DOAS Diagram. Moisture Removal Efficiency (MRE) is a measure of the energy efficiency of any dehumidification process. Moisture removal efficiency is the water vapor removed from air at a defined inlet air temperature and humidity, divided by the total energy consumed by the dehumidification equipment during the same time period, including all fan and pump energy needed to move air and fluids ...

  8. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    There are two major systems to classify ductwork airtightness, one based on European standards, the other based on ASHRAE standard 90.1-2010.Both are based on the leakage airflow rate at a given ductwork pressure divided by the product of the ductwork surface area and the same ductwork pressure raised to the power 0.65.

  9. Dedicated outdoor air system - Wikipedia

    en.wikipedia.org/wiki/Dedicated_outdoor_air_system

    Need for excess outdoor air flow and conditioning in VAV systems: When the multiple spaces equation of ASHRAE Standard 62.1-2004 is used, generally from 20-70% more outdoor air is required in an effort to assure proper room air distribution in all air systems than is required with a dedicated outdoor air systems.