enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Equivalent impedance transforms - Wikipedia

    en.wikipedia.org/wiki/Equivalent_impedance...

    An equivalent impedance is an equivalent circuit of an electrical network of impedance elements [note 2] which presents the same impedance between all pairs of terminals [note 10] as did the given network. This article describes mathematical transformations between some passive, linear impedance networks commonly found in electronic circuits.

  3. Impedance matching - Wikipedia

    en.wikipedia.org/wiki/Impedance_matching

    The formula for calculating the transformer turns ratio for this example is: ... is in parallel with the source impedance, ... to DC current. Reducing the output ...

  4. Electrical impedance - Wikipedia

    en.wikipedia.org/wiki/Electrical_impedance

    In electrical engineering, impedance is the opposition to alternating current presented by the combined effect of resistance and reactance in a circuit. [1]Quantitatively, the impedance of a two-terminal circuit element is the ratio of the complex representation of the sinusoidal voltage between its terminals, to the complex representation of the current flowing through it. [2]

  5. Miller theorem - Wikipedia

    en.wikipedia.org/wiki/Miller_theorem

    Dual Miller theorem actually expresses the fact that connecting a second current source producing proportional current = in parallel with the main input source and the impedance element changes the current flowing through it, the voltage and accordingly, the circuit impedance seen from the side of the input source.

  6. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  7. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The neutral current can be determined by adding the three phase currents together as complex numbers and then converting from rectangular to polar co-ordinates. If the three-phase root mean square (RMS) currents are I L 1 {\displaystyle I_{L1}} , I L 2 {\displaystyle I_{L2}} , and I L 3 {\displaystyle I_{L3}} , the neutral RMS current is:

  8. Quarter-wave impedance transformer - Wikipedia

    en.wikipedia.org/wiki/Quarter-wave_impedance...

    The quarter wave transformer is an alternative to a stub; but, whereas a stub is terminated in a short (or open) circuit and the length is chosen so as to produce the required impedance transformation, the λ/4 transformer is in series with the load and its length and characteristic impedance are designed to produce the required impedance ...

  9. Characteristic impedance - Wikipedia

    en.wikipedia.org/wiki/Characteristic_impedance

    The input impedance of an infinite line is equal to the characteristic impedance since the transmitted wave is never reflected back from the end. Equivalently: The characteristic impedance of a line is that impedance which, when terminating an arbitrary length of line at its output, produces an input impedance of equal value. This is so because ...