In power systems, harmonics are defined as positive integer multiples of the fundamental frequency. Thus, the third harmonic is the third multiple of the fundamental frequency. Harmonics in power systems are generated by non-linear loads. Semiconductor devices like transistors, IGBTs, MOSFETs, diodes, etc. are all non-linear loads. Further ...
It is used as a grounding transformer, creating a missing neutral connection from an ungrounded 3-phase system to permit the grounding of that neutral to an earth reference point; to perform harmonic mitigation, as they can suppress triplet (3rd, 9th, 15th, 21st, etc.) harmonic currents; [2] to supply 3-phase power as an autotransformer ...
The possible effects if the level of harmonics, known as total harmonic distortion becomes too high include damage to sensitive electronic equipment [5] and reduction in the efficiency of the HV transformer. [6] The efficiency of electrical loads can be improved by attenuating harmonics at the supply, or by preventing their generation.
In a step-up transformer, conversely, the load is attached across the full winding while the source is connected to a tap across a portion of the winding. For a step-up transformer, the subscripts in the above equations are reversed where, in this situation, N 2 {\displaystyle N_{2}} and V 2 {\displaystyle V_{2}} are greater than N 1 ...
Another example is the generation of higher-phase-order systems for large rectifier systems, to produce a smoother DC output and to reduce the harmonic currents in the supply. When three-phase is needed but only single-phase is readily available from the electricity supplier, a phase converter can be used to generate three-phase power from the ...
Using a star-to-delta or "wye-delta" connection of the transformer windings, the converter can operate with 12 pulses for each cycle in the AC supply, which eliminates numerous harmonic current components. The insulation of the transformer windings must be specially designed to withstand a large DC potential to earth.
If each phase has its own three-level converter, then a total of five levels can be created. This creates a very crude sine wave, however PWM still offer less harmonic generation (as the pulses are still on all five levels). Three-level converters can also be combined with transformers and phase shifting to create additional levels. [19]
Removing harmonics: Dy connection – D winding nullifies 3rd harmonics, preventing it to be reflected on Wye side. Parallel operations: All the transformers should have same phase rotation, vector group, tap setting & polarity of the winding. Ground fault Relay: A Dd transformer does not have neutral.