enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    In the North American electrical industry, conductors thicker than 4/0 AWG are generally identified by the area in thousands of circular mils (kcmil), where 1 kcmil = 0.5067 mm 2. The next wire size thicker than 4/0 has a cross section of 250 kcmil. A circular mil is the area of a wire one mil in diameter. One million circular mils is the area ...

  3. Circular mil - Wikipedia

    en.wikipedia.org/wiki/Circular_mil

    For example, one common wire size used in the NEC has a conductor diameter of 0.5 inches, or 500 mils, and thus a cross-section of = circular mils, written as 250 kcmil or 250 MCM, which is the first size larger than 0000 AWG used within the NEC.

  4. Wire gauge - Wikipedia

    en.wikipedia.org/wiki/Wire_gauge

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it The first attempt to adopt a geometrical system was made by Messrs Brown & Sharpe in 1855.

  5. Electrical length - Wikipedia

    en.wikipedia.org/wiki/Electrical_length

    The electrical length of a conductor determines when wave effects (phase shift along the conductor) are important. [ 4 ] : p.12–14 If the electrical length G {\displaystyle G} is much less than one, that is the physical length of a conductor is much shorter than the wavelength, say less than one tenth of the wavelength ( l < λ / 10 ...

  6. Electrical resistance and conductance - Wikipedia

    en.wikipedia.org/wiki/Electrical_resistance_and...

    where is the length of the conductor, measured in metres (m), A is the cross-sectional area of the conductor measured in square metres (m 2), σ is the electrical conductivity measured in siemens per meter (S·m −1), and ρ is the electrical resistivity (also called specific electrical resistance) of the material, measured in ohm-metres (Ω ...

  7. Standard wire gauge - Wikipedia

    en.wikipedia.org/wiki/Standard_wire_gauge

    No. 7/0, the largest size, is 0.50 in. (500 thou or 12.7 mm) dia., No. 1 is 0.30 in. (300 thou), and the smallest, No. 50, is 0.001 in. (1 thou or 25.4 µm). The system as a whole approximates an exponential curve, plotting diameter against gauge-number (each size is a approximately a constant multiple of the previous size). The weight per unit ...

  8. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  9. Skin effect - Wikipedia

    en.wikipedia.org/wiki/Skin_effect

    The same size conductor in aluminum has only 10% more resistance with 60 Hz AC than it does with DC. [14] Skin depth also varies as the inverse square root of the permeability of the conductor. In the case of iron, its conductivity is about 1/7 that of copper. However being ferromagnetic its permeability is about 10,000 times greater.