Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
The resistance of copper wire is approximately 1 ohms / 1000 feet for 10 AWG, 10 ohms / 1000 feet for 20 AWG, 100 ohms / 1000 feet for 30 AWG, and so on. [ 5 ] : 27 Because aluminum wire has a conductivity of approximately 61% of copper, an aluminum wire has nearly the same resistance as a copper wire that is two sizes ...
This improved conductivity over bare aluminum makes the copper-clad aluminium wire a good fit for radio frequency use. The skin effect is similarly exploited in copper-clad steel wire, such as the center conductors of many coaxial cables, which are commonly used for high frequency feedlines with high strength and conductivity requirements.
Aluminum alloys used for electrical conductors are only approximately 61% as conductive as copper of the same cross-section, but aluminum's density is 30.5% that of copper. Accordingly, one pound of aluminum has the same current carrying capacity as two pounds of copper. [ 3 ]
Aluminium conductors are still heavily used for bulk power transmission, power distribution, and large feeder circuits with heavy current loads, due to the various advantages they offer over copper wiring. Aluminium conductors both cost and weigh less than copper conductors, so a much larger cross sectional area can be used for the same weight ...
The designation NM XX-Y indicates, respectively, the type of sheathing (in this case, non-metallic), the size of the main conductors, and the total number of circuit conductors (exclusive of the grounding conductor). For example, NM 14-2 cable contains three conductors (two plus one ground) at 14 gauge, a size typically used for circuits ...
Power cables use stranded copper or aluminum conductors, although small power cables may use solid conductors in sizes of up to 1/0. (For a detailed discussion on copper cables, see: Copper wire and cable.). The cable may include uninsulated conductors used for the circuit neutral or for ground (earth) connection.
Class 2 refers to rigid stranded copper conductors as stipulated by British Standard BS EN 60228:2005 [2]) Insulation: Cross-linked polyethylene (XLPE) is used in a number of power cables because it has good water resistance and excellent electrical properties.