This is a list of insulation materials used around the world. Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.
Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value (in K⋅m 2 /W) is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]
Compressed straw bales have a wide range of documented R-value. R-value is a measurement of a materials insulating quality, higher the number the more insulating. The reported R-value ranges from 17–55 (in American units) or 3–9.6 (in SI) depending on the study, differing wall designs could be responsible for wide range in R-value.
The Straw Bale House, 1994). Using a straw bale in-fill sandwich roof greatly increases the R value. This compares very favorably with the R-19 (RSI-3.35) of a conventional 2 x 6 insulated wall. When using straw bales for construction, the bales must be tightly-packed and allowed to dry out sufficiently.
When baled, straw has moderate insulation characteristics (about R-1.5/inch according to Oak Ridge National Lab and Forest Product Lab testing). It can be used, alone or in a post-and-beam construction, to build straw bale houses. When bales are used to build or insulate buildings, the straw bales are commonly finished with earthen plaster.
This means that VIPs have about one-fifth the thermal conductivity of conventional insulation, and therefore about five times the thermal resistance per unit thickness. Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value ...
EPS is the most common of the foams used and has an R-value (thermal resistance) of about 4 °F·ft 2 ·h/Btu (equivalent to about 0.7 K·m 2 /W) per 25 mm thickness, which would give the 3.5 inches (89 mm) of foam in a 4.5-inch-thick (110 mm) panel an R value of 13.8 (caution: extrapolating R-values over thickness may be imprecise due to non ...
The cited values for straw bale R the value is with respect to a study that even the link referenced said it is questionable (circulation behind drywall facing changing value). As such, and since this page is talking about basic R-values and not combinational values, shouldn't the more accepted values be used?