Feedback system with a PD controller and a double integrator plant In systems and control theory , the double integrator is a canonical example of a second-order control system. [ 1 ] It models the dynamics of a simple mass in one-dimensional space under the effect of a time-varying force input u {\displaystyle {\textbf {u}}} .
In engineering, a transfer function (also known as system function [1] or network function) of a system, sub-system, or component is a mathematical function that models the system's output for each possible input. [2] [3] [4] It is widely used in electronic engineering tools like circuit simulators and control systems.
English: Step responses for a second order system defined by the transfer function: = + + where is the damping ratio and is the undamped natural frequency.The equations were obtained from here, plotted using maxima and edited in a text editor to insert the Greek alphabets in the plot.
The definition of the damping ratio and natural frequency presumes that the overall feedback system is well approximated by a second order system; i.e. the system has a dominant pair of poles. This is often not the case, so it is good practice to simulate the final design to check if the project goals are satisfied.
In signal processing, a digital biquad filter is a second order recursive linear filter, containing two poles and two zeros. "Biquad" is an abbreviation of "biquadratic", which refers to the fact that in the Z domain, its transfer function is the ratio of two quadratic functions:
The closed-loop transfer function is measured at the output. The output signal can be calculated from the closed-loop transfer function and the input signal. Signals may be waveforms, images, or other types of data streams. An example of a closed-loop block diagram, from which a transfer function may be computed, is shown below:
Mathematical analysis of the transfer function can describe how it will respond to any input. As such, designing a filter consists of developing specifications appropriate to the problem (for example, a second-order low-pass filter with a specific cut-off frequency), and then producing a transfer function that meets the specifications.