enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Hazen–Williams equation - Wikipedia

    en.wikipedia.org/wiki/Hazen–Williams_equation

    S foot of water per foot of pipe; P d = pressure drop over the length of pipe in psig (pounds per square inch gauge pressure) L = length of pipe in feet; Q = flow, gpm (gallons per minute) C = pipe roughness coefficient; d = inside pipe diameter, in (inches) Note: Caution with U S Customary Units is advised. The equation for head loss in pipes ...

  3. Fixture unit - Wikipedia

    en.wikipedia.org/wiki/Fixture_unit

    A Fixture Unit is not a flow rate unit but a design factor. A fixture unit is equal to 1 cubic foot (0.028 m 3) of water drained in a 1 + 1 ⁄ 4 inches (32 mm) diameter pipe over one minute. [2] One cubic foot of water is roughly 7.48 US gallons (28.3 L; 6.23 imp gal). A Fixture Unit is used in plumbing design for both water supply and waste ...

  4. International Plumbing Code - Wikipedia

    en.wikipedia.org/wiki/International_Plumbing_Code

    The IPC is the most widely used plumbing code in the United States and is also used as the basis for the plumbing code of several other countries [citation needed].Wide adoptions are important as they help reduce manufacturer and end-user costs by allowing the use of materials across a wide user base, thus allowing economies of scale in the production of materials used in construction.

  5. Nominal Pipe Size - Wikipedia

    en.wikipedia.org/wiki/Nominal_Pipe_Size

    Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...

  6. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]

  7. Total dynamic head - Wikipedia

    en.wikipedia.org/wiki/Total_dynamic_head

    In fluid dynamics, total dynamic head (TDH) is the work to be done by a pump, per unit weight, per unit volume of fluid.TDH is the total amount of system pressure, measured in feet, where water can flow through a system before gravity takes over, and is essential for pump specification.

  8. Hardy Cross method - Wikipedia

    en.wikipedia.org/wiki/Hardy_Cross_method

    The Hardy Cross method can be used to calculate the flow distribution in a pipe network. Consider the example of a simple pipe flow network shown at the right. For this example, the in and out flows will be 10 liters per second. We will consider n to be 2, and the head loss per unit flow r, and initial flow guess for each pipe as follows:

  9. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    K-Factors have also previously been calculated and published using the United States customary units of pound per square inch (psi) and gallon per minute (gpm). Within the United States, US measurements are still often used instead of metric.