enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    A fixation disparity is not constant within a certain observer, but can vary depending on the viewing conditions. If test prisms with increasing amount are placed in front of the observer’s eyes, the fixation disparity changes in the eso direction with base-in prisms and in the exo direction with base-out prisms (Fig. 3). These prisms force ...

  3. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  4. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    The strength of the prism is increased until the streak of the light passes through the centre of the prism, as the strength of the prism indicates the amount of deviation present. The Maddox rod is a handheld instrument composed of red parallel plano convex cylinder lens , which refracts light rays so that a point source of light is seen as a ...

  5. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2] Thus a prism of 1 Δ would produce 1 cm visible displacement at 100 cm, or 1 metre. This can be represented mathematically as: = ⁡ where is the amount of prism correction in prism dioptres, and is the angle of deviation of the light.

  6. Exophoria - Wikipedia

    en.wikipedia.org/wiki/Exophoria

    Exophoria. Exophoria is a form of heterophoria in which there is a tendency of the eyes to deviate outward. [1] During examination, when the eyes are dissociated, the visual axes will appear to diverge away from one another. [2] The axis deviation in exophoria is usually mild compared with that of exotropia.

  7. Cover test - Wikipedia

    en.wikipedia.org/wiki/Cover_test

    To ensure that the test is executed accurately and that the maximal amount of information is obtained, it is paramount that the appropriate fixation targets are used for near (approximately 33 cm (13 in)), distance (3 m (10 ft)) and far distance (>3 m (10 ft)) and also that a cover consisting of a black 'paddle' is used.

  8. Maddox wing - Wikipedia

    en.wikipedia.org/wiki/Maddox_Wing

    Maddox wing. The Maddox Wing is an instrument utilized by ophthalmologists, orthoptists and optometrists in the measurement of strabismus (misalignment of the eyes; commonly referred to as a squint or lazy eye by the lay person). It is a quantitative and subjective method of measuring the size of a strabismic deviation by dissociation of the ...

  9. Convergence insufficiency - Wikipedia

    en.wikipedia.org/wiki/Convergence_insufficiency

    Some cases of convergence insufficiency are successfully managed by prescription of eyeglasses, sometimes with therapeutic prisms. Pencil push-ups therapy is performed at home. The patient brings a pencil slowly to within 2–3 cm (0.79–1.18 in) of the eye just above the nose about fifteen minutes per day five times per week.