Search results
Results from the WOW.Com Content Network
A push-in compression coupling and tee.. Push-to-pull, push-to-connect, push-in, push-fit, or instant fittings are a type of easily removed compression fitting or quick connect fitting that allows an air (or water) line to be attached, nominally without the use of tools (a tool is still usually required for cutting tubing to length and removal).
A short piece of fire hose, usually 10 to 20 feet (6.1 m) long, of large diameter, greater than 2.5 inches (64 mm) and as large as 6 inches (150 mm), used to move water from a fire hydrant to the fire engine, when the fire apparatus is parked close to the hydrant.
Quick connect fittings are intended to be applied more easily than traditional fittings, requiring only that the pipes be pushed together firmly to lock the teeth of the fitting firmly. The teeth are forced deeper into the tubing when opposing force is applied to them, preventing their separation from the tubing. An o-ring provides a water ...
It is the most common type of fire hose coupling used in the United States. The male and female straight (non-tapered) threads screw together and the connection is sealed with a gasket. The type of threaded coupling with a pin-lug swivel used on fire hoses was first manufactured prior to 1873 in the U.S.:
The 100 mm (4-inch) and 125 mm (5-inch) Storz couplers have been specified in NFPA 1963, Standard for Fire Hose Connections, since the 1993 edition. U.S. cities that have fire hydrants with 125 mm Storz connectors include Raleigh, NC [5] and the City of Corvallis, OR (adapter on 4-inch threaded outlet). [6]
Fitting profiles have identifiable geometry on the male end, but care must be taken to use a compatible coupler. Couplers use springs and balls to lock mating nipples into place. A seal is effected using O-rings along the shaft of the nipple or by compression by the tip.
Push-to-pull fittings are easily removed compression fitting that allows pipes to be connected with minimal tools. These fittings are similar to regular compression fittings but use an O-ring for sealing and a grip ring to hold the pipe. The main advantage is that it can easily be removed and re-used, it is easy to assemble, and the joints are ...
An empty fire extinguisher which was not replaced for years. Most countries in the world require regular fire extinguisher maintenance by a competent person to operate safely and effectively, as part of fire safety legislation. Lack of maintenance can lead to an extinguisher not discharging when required, or rupturing when pressurized.