enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    The on-test failure rates on a cable system are in the range of 0.2 to 4% for 30 min tests performed at the IEEE 400.2 voltage levels. IEEE Std. 400.2 provides suggested time and voltage test levels but exact parameters are not possible since defect growth rates are not known and can vary widely.

  3. Cross-linked polyethylene - Wikipedia

    en.wikipedia.org/wiki/Cross-linked_polyethylene

    A cross-linked polyethylene (PEX) pipe. Cross-linked polyethylene, commonly abbreviated PEX, XPE or XLPE, is a form of polyethylene with cross-links.It is used predominantly in building services pipework systems, hydronic radiant heating and cooling systems, domestic water piping, insulation for high tension (high voltage) electrical cables, and baby play mats.

  4. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    Prior to 2013 IS 201-4:2001 ( I.S. 201 part 4: PVC and Low Smoke Halogen Free Sheathed cables for fixed wiring) permitted both the UK style of twin and earth, and also a version with a CPC with a cross-section equal to that of the main conductors and insulated in green and yellow inside the full length of the cable.

  5. High-voltage cable - Wikipedia

    en.wikipedia.org/wiki/High-voltage_cable

    High voltage is defined as any voltage over 1000 volts. [3] Those of 2 to 33 kV are usually called medium voltage cables, those over 50 kV high voltage cables.. Modern HV cables have a simple design consisting of a few parts: the conductor, the conductor shield, the insulation, the insulation shield, the metallic shield, and the jacket.

  6. Mineral-insulated copper-clad cable - Wikipedia

    en.wikipedia.org/wiki/Mineral-insulated_copper...

    PVC-sheathed MICC cable. Conductor cross section area is 1.5 mm 2; overall diameter is 7.2 mm. Mineral-insulated cables at a panel board. Mineral-insulated copper-clad cable is a variety of electrical cable made from copper conductors inside a copper sheath, insulated by inorganic magnesium oxide powder.

  7. Cable fault location - Wikipedia

    en.wikipedia.org/wiki/Cable_fault_location

    The conventionally used aid in cable fault testing and location is the cable test van. The van is installed with conventional cable measuring systems for quickly reaching the location of any cable fault. In 20 years that followed, over 2000 fault location vehicles were manufactured, more than half of which were intended for the former USSR.

  8. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60055 Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) IEC 60059 IEC standard current ratings; IEC 60060 High-voltage test techniques; IEC 60061 Lamp caps and holders together with gauges for the control of interchangeability and safety

  9. Tri-rated cable - Wikipedia

    en.wikipedia.org/wiki/Tri-rated_cable

    BS 6231 is a British Standard, last revised in 2006 by the BSI Group. [4] This standard specifies the performance and construction requirements of electrical cables that are single core, non-sheathed, PVC-insulated and rated 600/1000 V. Wire meeting the requirements of type CK of this standard is used as tri-rated wire.