Search results
Results from the WOW.Com Content Network
The original 1977 converter was one of the first thyristor-based HVDC schemes to be put into operation in the world and used oil-insulated, oil-cooled outdoor thyristor valves supplied by Hitachi (60 Hz end) and Toshiba (50 Hz end). A special workshop was provided on the site, in which valve maintenance (for example replacing failed thyristors ...
One of the disadvantages of 16.7 Hz locomotives as compared to 50 Hz or 60 Hz locomotives is the heavier transformer required to reduce the overhead line voltage to that used by the motors and their speed control gear. Low frequency transformers need to have heavier magnetic cores and larger windings for the same
Some lines in the United States have been electrified at 12.5 kV 60 Hz or converted from 11 kV 25 Hz to 12.5 kV 60 Hz. Use of 60 Hz allows direct supply from the 60 Hz utility grid yet does not require the larger wire clearance for 25 kV 60 Hz or require dual-voltage capability for trains also operating on 11 kV 25 Hz lines. Examples are:
Aircraft often use 400 Hz power internally, so 50 Hz or 60 Hz to 400 Hz frequency conversion is needed for use in the ground power unit used to power the airplane while it is on the ground. Conversely, internal 400 Hz internal power may be converted to 50 Hz or 60 Hz for convenience power outlets available to passengers during flight.
Often airplanes use 400 Hz power so a 50 Hz or 60 Hz to 400 Hz frequency converter is needed for use in the ground power unit used to power the airplane while it is on the ground. Airlines might also utilize the converters to provide in-air wall current to passengers for use with laptops and the like.
The system was mains frequency dependent, so a 50 Hz and 60 Hz versions were available (50 Hz in the UK, 60 Hz in the US and Canada). The Zero 1 system supplied the track with a 18 V sinusoidal alternating current at the local mains frequency with a 32-bit control word replacing every third cycle.
The waveform of 230 V and 50 Hz compared with 120 V and 60 Hz. The utility frequency, (power) line frequency (American English) or mains frequency (British English) is the nominal frequency of the oscillations of alternating current (AC) in a wide area synchronous grid transmitted from a power station to the end-user.
At low frequencies (such as the line frequency of 50 or 60 Hz), designers can usually ignore the skin effect. For these frequencies, the skin effect is only significant when the conductors are large, more than 0.3 inches (7.6 mm) in diameter. Switching power supplies must pay more attention to the skin effect because it is a source of power loss.