  2. Three-prong adaptor - Wikipedia

    en.wikipedia.org/wiki/Three-prong_adaptor

    The ground tab is designed to be attached to the outlet faceplate screw, which is supposed to be connected to the building electrical ground. A cheater plug , AC ground lifter or three-prong/two-prong adapter is an adapter that allows a NEMA 5-15P grounding -type plug (three prongs) to connect to a NEMA 1-15R non-grounding receptacle (two slots).

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  4. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    All NEMA 6 devices are three-wire grounding devices (hot-hot-ground) used for 208 and 240 V circuits and rated for 250 V maximum, with the 6-15, 6-20 and 6-30 being grounding versions of the 2-15, 2-20 and 2-30, respectively. The 6-15 resembles the 5-15, but with collinear horizontal pins, spaced 23 ⁄ 32 in (18.3 mm) center-to-center. The 20 ...

  5. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    "Switched socket-outlets and connectors with or without interlock" applies to self-contained products that combine within a single enclosure, a socket-outlet or connector according to IEC 60309-1 or IEC 60309-2 and a switching device, with a rated operating voltage not exceeding 1000 VDC or VAC and 500 Hz, and a rated current not exceeding 800 A.

  6. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    The NEC also permits grounding-type receptacles in non-grounded wiring protected by a GFCI; this only applies when old non-grounded receptacles are replaced with grounded receptacles, and the new receptacles must be marked with 'No equipment ground' and 'GFCI Protected' . 240 V receptacle faces

  7. Bootleg ground - Wikipedia

    en.wikipedia.org/wiki/Bootleg_ground

    A receptacle with a bootleg ground. In building wiring installed with separate neutral and protective ground bonding conductors (a TN-S network), a bootleg ground (or a false ground) is a connection between the neutral side of a receptacle or light fixture and the ground lug or enclosure of the wiring device. [1]: 287

  8. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Ground is a safety conductor with a low impedance path to earth. It is often called the "ground wire," or safety ground. It is either bare or has green insulation. [1] Leg as in "hot leg" refers to one of multiple hot conductors in an electrical system.

  9. AC power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/AC_power_plugs_and_sockets

    The ground hole is officially D-shaped, although some round holes exist and many plugs have round ground pins. Both current-carrying blades on grounding plugs may be narrow, since the ground pin enforces polarity, but outlets have a wider opening for the neutral blade to prevent ungrounded polarized plugs from being put in backwards.