A North American power strip with two USB power ports that includes a built in surge protector. A power strip (also known as a multi-socket, power board and many other variations [a]) is a block of electrical sockets that attaches to the end of a flexible cable (typically with a mains plug on the other end), allowing multiple electrical devices to be powered from a single electrical socket.
The "local" earth/ground electrode provides "system grounding" [13] at each building where it is installed. The "Grounded" current carrying conductor is the system "neutral". [clarification needed] Australian and New Zealand standards use a modified protective multiple earthing (PME [14]) system called multiple earthed neutral (MEN).
There should be a break in copper between this strip, and the main ground plane of the circuit. The two should be connected at only one point. This way, if there is a large current between connector shields, it will not pass through the ground plane of the circuit. A star topology should be used for ground distribution, avoiding loops.
Power strips are handy, but they’re only designed for short-term use with low-power items like your charger, not microwaves and freezers. Power strips are handy, but they’re only designed for ...
Belkin also sells wall chargers, car chargers, charging stations, power banks, surge protectors, power strips, and wireless chargers for smartphones, tablets, smartwatches, laptops, computers, and other electronic devices. In 2016, Belkin released an iPhone-compatible adapter for simultaneous iPhone charging and headphone use. [29]
Electrical equipment may be designed with a floating ground for one of several reasons. One is safety. For example, a low-voltage DC power supply, such as a mobile phone charger, is connected to the mains through a transformer of one type or another, and there is no direct electrical connection between the current return path on the low-voltage side and physical ground (earth).
A ground connection that is missing or of inadequate capacity may not provide the protective functions as intended during a fault in the connected equipment. Extra connections between ground and circuit neutral may result in circulating current in the ground path, stray current introduced in the earth or in a structure, and stray voltage.
Ground-fault circuit interrupter (GFCI) protection is required on receptacles in wet locations and locations where there exists an easy path for fault current to travel to earth. This includes all receptacles intended to service kitchen counter surfaces, crawl spaces at or below grade level, basements, garages and accessory buildings, bathrooms ...