  1. Results from the WOW.Com Content Network
  2. Ion-to-photon detector - Wikipedia

    en.wikipedia.org/wiki/Ion-to-photon_detector

    Ion-to-photon detectors may also detect ions with a mass of up to around 20,000 Da, better than microchannel plates. However, the resolution of the mass spectrum from an IPD equipped spectrometer is slightly lower. The noise in the spectrum, which may come from unfocused, slow speed ions, is also slightly higher.

  3. Helium mass spectrometer - Wikipedia

    en.wikipedia.org/wiki/Helium_mass_spectrometer

    Helium is used as a tracer because it penetrates small leaks rapidly. Helium also has the properties of being non-toxic, chemically inert and present in the atmosphere only in minute quantities (5 ppm). Typically a helium leak detector will be used to measure leaks in the range of 10 −5 to 10 −12 Pa·m 3 ·s −1.

  4. Mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrometry

    Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a mass spectrum, a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is used in many different fields and is applied to pure samples as well as complex mixtures.

  5. Explosives trace detector - Wikipedia

    en.wikipedia.org/wiki/Explosives_trace_detector

    Recently, mass spectrometry (MS) has emerged as another ETD technology. Adoption of mass spectrometry should lower false alarms rates often associated with ETD due to the higher resolution of the core technology. [citation needed] It also uses a non-radioactive ionization method generally secondary electrospray ionization (SESI-MS).

  6. Microchannel plate detector - Wikipedia

    en.wikipedia.org/wiki/Microchannel_plate_detector

    A microchannel plate within a Finnigan MAT 900 sector mass spectrometer position-and-time-resolved-ion-counting (PATRIC) scanning array detector. An external voltage divider is used to apply 100 volts to the acceleration optics (for electron detection), each MCP, the gap between the MCPs, the backside of the last MCP, and the collector .

  7. Triple quadrupole mass spectrometer - Wikipedia

    en.wikipedia.org/wiki/Triple_quadrupole_mass...

    Both, the first mass analyzer and the collision cell are continuously exposed to ions from the source, in a time independent manner. [4] It is once the ions move into the third mass analyzer that time dependence becomes a factor. [4] The first quadrupole mass filter, Q1, is the primary m/z selector after the sample leaves the ionization source.

  8. Daly detector - Wikipedia

    en.wikipedia.org/wiki/Daly_detector

    A Daly detector is a gas-phase ion detector that consists of a metal "doorknob", a scintillator (phosphor screen) and a photomultiplier. [1] It was named after its inventor Norman Richard Daly. Daly detectors are typically used in mass spectrometers .

  9. High-performance liquid chromatography - Wikipedia

    en.wikipedia.org/wiki/High-performance_liquid...

    Trifluoroacetic acid (TFA) as additive to the mobile phase is widely used for complex mixtures of biomedical samples, mostly peptides and proteins, using mostly UV based detectors. They are rarely used in mass spectrometry methods, due to residues it can leave in the detector and solvent delivery system, which interfere with the analysis and ...