enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. INCA (software) - Wikipedia

    en.wikipedia.org/wiki/INCA_(Software)

    A host of functions required for ECU software calibration, such as interface-dependent calibration methods, calibration data management, measurement data visualization and analysis, ECU programming, vehicle bus monitoring, as well as remote control through standard interfaces, are part of the product's functional complement.

  3. Cyclocomputer - Wikipedia

    en.wikipedia.org/wiki/Cyclocomputer

    In 1895, Curtis H. Veeder invented the Cyclometer. [1] [2] [3] The Cyclometer was a simple mechanical device that counted the number of rotations of a bicycle wheel.[4] [5] A cable transmitted the number of rotations of the wheel to an analog odometer visible to the rider, which converted the wheel rotations into the number of miles traveled according to a predetermined formula.

  4. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  5. Tachometer - Wikipedia

    en.wikipedia.org/wiki/Tachometer

    In many countries, tractors are required to have a speedometer for use on a road. To save fitting a second dial, the vehicle's tachometer is often marked with a second scale in units of speed. This scale is only accurate in a certain gear, but since many tractors only have one gear that is practical for use on-road, this is sufficient.

  6. Pointing stick - Wikipedia

    en.wikipedia.org/wiki/Pointing_stick

    Additional pressure again moves the pointer, but the calibration may occur again, requiring even more force. If the user releases pressure at this point, the change will be interpreted as an instruction to move the opposite direction. In time, the software will re-calibrate and stop the motion.

  7. Deadweight tester - Wikipedia

    en.wikipedia.org/wiki/Deadweight_tester

    A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston. Deadweight testers are secondary standards which means that the pressure measured by a deadweight tester is defined through other quantities: length, mass and time.

  8. Robot calibration - Wikipedia

    en.wikipedia.org/wiki/Robot_calibration

    Parametric robot calibration is the process of determining the actual values of kinematic and dynamic parameters of an industrial robot (IR). Kinematic parameters describe the relative position and orientation of links and joints in the robot while the dynamic parameters describe arm and joint masses and internal friction.

  9. Electro-galvanic oxygen sensor - Wikipedia

    en.wikipedia.org/wiki/Electro-galvanic_oxygen_sensor

    Pre-dive calibration of the cells can only check response to partial pressures up to 100% at atmospheric pressure, or 1 bar. As the set points are commonly in the range of 1.2 to 1.6 bar, [6] special hyperbaric calibration equipment would be required to reliably test the response at the set-points. This equipment is available, but is expensive ...