enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Variable speed fire pump controller - Wikipedia

    en.wikipedia.org/wiki/Variable_speed_fire_pump...

    Conserve Water During TestingNFPA-25 requires that the fire pump controller is operated for 10 minutes each week. This ends up using a substantial amount of water in buildings that have static pressures greater than 175 PSI and relies on a system relief valve to control the pressure: (50–100% of the rating of the pump) × (10minutes) × ...

  3. Sprinkler fitting - Wikipedia

    en.wikipedia.org/wiki/Sprinkler_fitting

    Sprinkler fitting is a skilled trade that consists of assembling, installing, testing, repairing, inspecting, and certifying automatic fire suppression systems and their associated piping in commercial, industrial and residential buildings.

  4. Water flow test - Wikipedia

    en.wikipedia.org/wiki/Water_flow_test

    A water flow test, also known as a hydrant flow test, [1] is a way to measure the water supply available at a building site, usually for the purposes of installing a water based fire protection system (fire sprinkler system). The most common test involves measuring the flow of water flowing out of a municipal fire hydrant (measured in litres or ...

  5. National Fire Protection Association - Wikipedia

    en.wikipedia.org/wiki/National_Fire_Protection...

    The committee's initial report evolved into NFPA 13, Standard for the Installation of Sprinkler Systems, the most widely used fire sprinkler standard. [ 6 ] Around 1904, the NFPA began to expand its membership from affiliates of fire insurance companies to many other organizations and individuals, and also expanded its mission beyond ...

  6. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...

  7. Fire investigation - Wikipedia

    en.wikipedia.org/wiki/Fire_investigation

    The National Fire Protection Association (NFPA), through a document known as NFPA 1033, Standard for Professional Requirements for Fire Investigator, publishes minimum requirements for the knowledge skills and ability of a fire investigator. Principal among these is a 16-point list of areas in which a fire investigator is required to have ...

  8. Life Safety Code - Wikipedia

    en.wikipedia.org/wiki/Life_Safety_Code

    The publication Life Safety Code, known as NFPA 101, is a consensus standard widely adopted in the United States. [according to whom?] It is administered, trademarked, copyrighted, and published by the National Fire Protection Association and, like many NFPA documents, is systematically revised on a three-year cycle.

  9. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    In fire protection engineering, the K-factor formula is used to calculate the volumetric flow rate from a nozzle. Spray nozzles can for example be fire sprinklers or water mist nozzles, hose reel nozzles, water monitors and deluge fire system nozzles.