Search results
Results from the WOW.Com Content Network
That is, observed temperatures above 60 °F (or the base temperature used) typically correlate with a correction factor below "1", while temperatures below 60 °F correlate with a factor above "1". This concept lies in the basis for the kinetic theory of matter and thermal expansion of matter , which states as the temperature of a substance ...
A correction can be applied to the measured length to obtain the correct length. The correction of the tape length due to change in temperature is given by: = Where: is the correction to be applied to the tape due to temperature;
The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.
Residual magnetic flux density or B r changes with temperature and it is one of the important characteristics of magnet performance. Some applications, such as inertial gyroscopes and traveling-wave tubes (TWTs), need to have constant field over a wide temperature range. The reversible temperature coefficient (RTC) of B r is defined as:
A correction to Newton's law concerning convection for larger temperature differentials by including an exponent, was made in 1817 by Dulong and Petit. [6] These men are better-known for their formulation of the Dulong–Petit law concerning the molar specific heat capacity of a crystal.)
If the gas is heated so that the temperature of the gas goes up to T 2 while the piston is allowed to rise to V 2 as in Figure 1, then the pressure is kept the same in this process due to the free floating piston being allowed to rise making the process an isobaric process or constant pressure process. This Process Path is a straight horizontal ...
In thermodynamics, a departure function is defined for any thermodynamic property as the difference between the property as computed for an ideal gas and the property of the species as it exists in the real world, for a specified temperature T and pressure P. Common departure functions include those for enthalpy, entropy, and internal energy.
In fluid dynamics, the Cunningham correction factor, or Cunningham slip correction factor (denoted C), is used to account for non-continuum effects when calculating the drag on small particles. The derivation of Stokes' law , which is used to calculate the drag force on small particles, assumes a no-slip condition which is no longer correct at ...