Search results
Results from the WOW.Com Content Network
Mass spectral interpretation is the method employed to identify the chemical formula, characteristic fragment patterns and possible fragment ions from the mass spectra. [1] [2] Mass spectra is a plot of relative abundance against mass-to-charge ratio. It is commonly used for the identification of organic compounds from electron ionization mass ...
Electron ionization mass spectrum of toluene. Note parent peak corresponding to molecular mass M = 92 (C 7 H 8 +) and highest peak at M-1 = 91 (C 7 H 7 +, quasi-stable tropylium cation). A mass spectrum is a histogram plot of intensity vs. mass-to-charge ratio (m/z) in a chemical sample, [1] usually acquired using an instrument called a mass ...
Ion mobility spectrometry-mass spectrometry (IMS/MS or IMMS) is a technique where ions are first separated by drift time through some neutral gas under an applied electrical potential gradient before being introduced into a mass spectrometer. [43] Drift time is a measure of the collisional cross section relative to the charge of the ion.
Chlorine is a toxic gas that attacks the respiratory system, eyes, and skin. [126] Because it is denser than air, it tends to accumulate at the bottom of poorly ventilated spaces. Chlorine gas is a strong oxidizer, which may react with flammable materials. [127] [128]
A mass chromatogram is a representation of mass spectrometry data as a chromatogram, where the x-axis represents time and the y-axis represents signal intensity. [1] The source data contains mass information; however, it is not graphically represented in a mass chromatogram in favor of visualizing signal intensity versus time.
Chlorine (17 Cl) has 25 isotopes, ranging from 28 Cl to 52 Cl, and two isomers, 34m Cl and 38m Cl. There are two stable isotopes, 35 Cl (75.8%) and 37 Cl (24.2%), giving chlorine a standard atomic weight of 35.45.
The mass defect used in nuclear physics is different from its use in mass spectrometry. In nuclear physics, the mass defect is the difference in the mass of a composite particle and the sum of the masses of its component parts. In mass spectrometry the mass defect is defined as the difference between the exact mass and the nearest integer mass.
In mass spectrometry, direct analysis in real time (DART) is an ion source that produces electronically or vibronically excited-state species from gases such as helium, argon, or nitrogen that ionize atmospheric molecules or dopant molecules. The ions generated from atmospheric or dopant molecules undergo ion-molecule reactions with the sample ...