RAIS stripes and mirrors application code and memory across an array of ordinary servers using the standard RAID schemata of level 0, level 1, level 5, level 1+0. This is possible through a memory management system called Versioned Memory. [citation needed] Data blocks of each stream are striped across the array servers.
The four-drive example is identical to a standard RAID 1+0 array, while the three-drive example is a software implementation of RAID 1E. The two-drive example is equivalent to RAID 1. [13] The driver also supports a "far" layout, in which all the drives are divided into f sections. All the chunks are repeated in each section but are switched in ...
Diagram of a RAID 1 setup. RAID 1 consists of an exact copy (or mirror) of a set of data on two or more disks; a classic RAID 1 mirrored pair contains two disks.This configuration offers no parity, striping, or spanning of disk space across multiple disks, since the data is mirrored on all disks belonging to the array, and the array can only be as big as the smallest member disk.
RAID (/ r eɪ d /; redundant array of inexpensive disks or redundant array of independent disks) [1] [2] is a data storage virtualization technology that combines multiple physical data storage components into one or more logical units for the purposes of data redundancy, performance improvement, or both.
RAID 01, also called RAID 0+1, is a RAID level using a mirror of stripes, achieving both replication and sharing of data between disks. [3] The usable capacity of a RAID 01 array is the same as in a RAID 1 array made of the same drives, in which one half of the drives is used to mirror the other half.
In some RAID configurations, such as RAID 0, failure of a single member drive of the RAID array causes all stored data to be lost. In other RAID configurations, such as a RAID 5 that contains distributed parity and provides redundancy , if one member drive fails the data can be restored using the other drives in the array.
A flawed RAID 5/6 also exists, but can result in data loss.) [10] For RAID 1, the devices must have complementary sizes. For example, a filesystem spanning two 500 GB devices and one 1 TB device could provide RAID1 for all data, while a filesystem spanning a 1 TB device and a single 500 GB device could only provide RAID1 for 500 GB of data.
RAID stands for redundant array of independent disks (or, formerly, redundant array of inexpensive disks). RAID levels may refer to: Standard RAID levels, all the RAID configurations defined in the Common RAID Disk Drive Format standard, which is maintained by the Storage Networking Industry Association; Nested RAID levels, RAID configurations ...