Search results
Results from the WOW.Com Content Network
Corneal pachymetry is the process of measuring the thickness of the cornea.A pachymeter is a medical device used to measure the thickness of the eye's cornea.It is used to perform corneal pachymetry prior to refractive surgery, for Keratoconus screening, LRI surgery [1] and is useful in screening for patients suspected of developing glaucoma among other uses.
Pellucid marginal degeneration is diagnosed by corneal topography. Corneal pachymetry may be useful in confirming the diagnosis. Treatment usually consists of vision correction with eyeglasses or contact lenses. Intacs implants, corneal collagen cross-linking, and corneal transplant surgery are additional options.
Corneal topography, also known as photokeratoscopy or videokeratography, is a non-invasive medical imaging technique for mapping the anterior curvature of the cornea, the outer structure of the eye. Since the cornea is normally responsible for some 70% of the eye's refractive power , [ 1 ] its topography is of critical importance in determining ...
The Heidelberg Retinal Tomography is a diagnostic procedure used in ophthalmology.The Heidelberg Retina Tomograph (HRT) is an ophthalmological confocal point scanning laser ophthalmoscope [1] for examining the cornea and certain areas of the retina using different diagnostic modules (HRT retina, HRT cornea, HRT glaucoma).
The central corneal power is the second important factor in the calculation formula. To simplify the calculation, the cornea is assumed to be a thin spherical lens with a fixed anterior to posterior corneal curvature ratio and an index of refraction of 1.3375. Central corneal power can be measured by keratometry or corneal topography.
open angle between cornea and iris AC 3/4: Grade 3 anterior chamber angle: AC 2/4: Grade 2 anterior chamber angle: AC 1/4: Grade 1 anterior chamber angle: AC 0/4: Grade 0 anterior chamber angle: closed angle between cornea and iris AC/A: Accommodative convergence / Accommodation ratio the portion of the range of convergence that occurs in ...
Specifically, it could be inflammation in the cornea or certain glands, membranes or substances that make up tears. Inflammation in these spots can cause cells to die or damage tissues or nerves ...
Pachymetry ≥ 400 μm; Stage 3 Induced myopia and/or astigmatism between 8.01 and 10.00 D; K-reading > 53.00 D; Pachymetry 200 to 400 μm; Stage 4 Refraction not measurable; K-reading > 55.00 D; Central scars; Pachymetry ≤ 200 μm; Stage is determined if one of the characteristics applies. Corneal thickness is the thinnest measured spot of ...