  2. Corneal pachymetry - Wikipedia

    en.wikipedia.org/wiki/Corneal_pachymetry

    Corneal pachymetry is the process of measuring the thickness of the cornea.A pachymeter is a medical device used to measure the thickness of the eye's cornea.It is used to perform corneal pachymetry prior to refractive surgery, for Keratoconus screening, LRI surgery [1] and is useful in screening for patients suspected of developing glaucoma among other uses.

  3. Intraocular pressure - Wikipedia

    en.wikipedia.org/wiki/Intraocular_pressure

    Measured values of intraocular pressure are influenced by corneal thickness and rigidity. [5] [6] As a result, some forms of refractive surgery (such as photorefractive keratectomy) can cause traditional intraocular pressure measurements to appear normal when in fact the pressure may be abnormally high. A newer transpalpebral and transscleral ...

  4. Intraocular lens power calculation - Wikipedia

    en.wikipedia.org/wiki/Intraocular_lens_power...

    To simplify the calculation, the cornea is assumed to be a thin spherical lens with a fixed anterior to posterior corneal curvature ratio and an index of refraction of 1.3375. Central corneal power can be measured by keratometry or corneal topography. Corneal radius of curvature relates to corneal power with the equation: r = 337.5/K. [3]

  5. Pellucid marginal degeneration - Wikipedia

    en.wikipedia.org/wiki/Pellucid_marginal_degeneration

    However, it may not be as specific as corneal pachymetry, because corneal topography only evaluates the degree and distribution of surface irregularities on the cornea, not the thickness of the cornea. [5] Corneal topography may show a "crab claw-like" appearance, a finding that is seen in both keratoconus and in pellucid marginal degeneration.

  6. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    The machine uses this value to correct for the effects of the cornea on measurement. [20] In a population based study in healthy children that compared non-contact IOP measuring tonometer, including ORA and CORVIS with a contact tonometer, GAT, which is a routine instrument for IOP measurement.

  7. Keratoconus - Wikipedia

    en.wikipedia.org/wiki/Keratoconus

    Pachymetry ≥ 400 μm; Stage 3 Induced myopia and/or astigmatism between 8.01 and 10.00 D; K-reading > 53.00 D; Pachymetry 200 to 400 μm; Stage 4 Refraction not measurable; K-reading > 55.00 D; Central scars; Pachymetry ≤ 200 μm; Stage is determined if one of the characteristics applies. Corneal thickness is the thinnest measured spot of ...

  8. Scheimpflug principle - Wikipedia

    en.wikipedia.org/wiki/Scheimpflug_principle

    Figure 1. With a normal camera, when the subject is not parallel to the image plane, only a small region is in focus. Figure 2. The angles of the Scheimpflug principle, using the example of a photographic lens Figure 3. Rotation of the plane of focus Figure 4. Rotation-axis distance and angle of the PoF

  9. Corneal topography - Wikipedia

    en.wikipedia.org/wiki/Corneal_topography

    Corneal topography, also known as photokeratoscopy or videokeratography, is a non-invasive medical imaging technique for mapping the anterior curvature of the cornea, the outer structure of the eye. Since the cornea is normally responsible for some 70% of the eye's refractive power , [ 1 ] its topography is of critical importance in determining ...