enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    It only comes in 1/2" & 3/4" trade sizes, whereas FMC is sized 1/2" ~ 4" trade sizes. NEC 360.2 describes it as: "A raceway that is circular in cross section, flexible, metallic and liquidtight without a nonmetallic jacket." Liquidtight flexible nonmetallic conduit (LFNC) refers to several types of flame-resistant non-metallic tubing. Interior ...

  3. Nominal Pipe Size - Wikipedia

    en.wikipedia.org/wiki/Nominal_Pipe_Size

    Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...

  4. Knob-and-tube wiring - Wikipedia

    en.wikipedia.org/wiki/Knob-and-tube_wiring

    The conduit methods were known to be of better quality, but cost significantly more than K&T. [2] In 1909, flexible armored cable cost about twice as much as K&T, and conduit cost about three times the price of K&T. [6] Knob and tube wiring persisted since it allowed owners to wire a building for electricity at lower cost.

  5. NEMA enclosure types - Wikipedia

    en.wikipedia.org/wiki/NEMA_enclosure_types

    3: Weather-resistant. Protects against falling dirt and windblown dust, against weather hazards such as rain, sleet and snow, and is undamaged by the formation of ice. Used outdoors on ship docks, in construction work, and in tunnels and subways. 3R: As 3, but omits protection against windblown dust. 3S: As 3, but also operable when laden with ice.

  6. IEC 60364 - Wikipedia

    en.wikipedia.org/wiki/IEC_60364

    IEC 60364 Electrical Installations for Buildings is the International Electrotechnical Commission (IEC)'s international standard on electrical installations of buildings.This standard is an attempt to harmonize national wiring standards in an IEC standard and is published in the European Union by CENELEC as "HD 60364".

  7. ANSI device numbers - Wikipedia

    en.wikipedia.org/wiki/ANSI_device_numbers

    [3] For device 16, the suffix letters further define the device: the first suffix letter is 'S' for serial or 'E' for Ethernet. The subsequent letters are: 'C' security processing function (e.g. VPN, encryption), 'F' firewall or message filter, 'M' network managed function, 'R' rotor, 'S' switch and 'T' telephone component.

  8. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    This does not include the uninsulated ground wire. For instance, if the cable lists "12-2 AWG", it means there are two insulated 12-gauge wires (a black and a white wire), plus a ground wire. If the label says "12-3", this cable has four conductors—three 12-gauge insulated wires and a bare copper ground wire. [5]

  9. Bus duct - Wikipedia

    en.wikipedia.org/wiki/Bus_duct

    A plug-in bus duct system or busway can have disconnect switches and other devices mounted on it, for example, to distribute power along a long building. Many forms of busway allow plug-in devices such as switches and motor starters to be easily moved; this provides flexibility for changes on an assembly line, for example. [4]