Search results
Results from the WOW.Com Content Network
The measured flash point will actually vary with the height of the flame above the liquid surface and, at sufficient height, the measured flash point temperature will coincide with the fire point. The best-known example is the Cleveland open cup (COC).
Those with flash points above 37.8 °C/100 °F and below 93.3 °C/200 °F were classified as combustible liquids. [2] [3] Studies show that the actual measure of a liquid's flammability, its flash point, is dependent on the local air pressure, meaning that at higher altitudes where the air pressure is lower, the flash point is also lower. [4]
Class 3: Flammable Liquids A flammable liquid is a liquid having a flash point of not more than 60 °C (140 °F), or any material in a liquid phase with a flash point at or above 37.8 °C (100 °F) that is intentionally heated and offered for transportation or transported at or above its flash point in a bulk packaging. The following exceptions ...
For example, in the United States flammable liquids, by definition, have a flash point below 100 °F (38 °C)—where combustible liquids have a flash point above 100 °F (38 °C). Flammable solids are solids that are readily combustible, or may cause or contribute to fire through friction.
A carbon dioxide fire extinguisher rated for flammable liquids and gasses. Class B fires are those where the fuel is flammable or combustible liquid. The US system includes flammable gases in their "Class B". [3] In the European/Australian system, flammable liquids are designated "Class B" having flash point less than 100 °C (212 °F). [4]
A 5% displayed LFL reading for methane, for example, would be equivalent to 5% multiplied by 4.4%, or approximately 0.22% methane by volume at 20 degrees C. Control of the explosion hazard is usually achieved by sufficient natural or mechanical ventilation, to limit the concentration of flammable gases or vapors to a maximum level of 25% of ...
The fire point, or combustion point, of a fuel is the lowest temperature at which the liquid fuel will continue to burn for at least five seconds after ignition by an open flame of standard dimension. [1] At the flash point, a lower temperature, a substance will ignite briefly, but vapour might not be produced at a rate to sustain the fire ...
Flashover occurs when the majority of the exposed surfaces in a space are heated to their autoignition temperature and emit flammable gases (see also flash point). Flashover normally occurs at 500 °C (932 °F) or 590 °C (1,100 °F) for ordinary combustibles and an incident heat flux at floor level of 20 kilowatts per square metre (2.5 hp/sq ft).