Search results
Results from the WOW.Com Content Network
Reference ranges (reference intervals) for blood tests are sets of values used by a health professional to interpret a set of medical test results from blood samples. Reference ranges for blood tests are studied within the field of clinical chemistry (also known as "clinical biochemistry", "chemical pathology" or "pure blood chemistry"), the ...
The AST/ALT ratio or De Ritis ratio is the ratio between the concentrations of two enzymes, aspartate transaminase (AST) and alanine transaminase, aka alanine aminotransferase (ALT), in the blood of a human or animal. It is used as one of several liver function tests, and measured with a blood test.
Anion gap can be classified as either high, normal or, in rare cases, low. Laboratory errors need to be ruled out whenever anion gap calculations lead to results that do not fit the clinical picture. Methods used to determine the concentrations of some of the ions used to calculate the anion gap may be susceptible to very specific errors.
In alcoholic liver disease, the mean ratio is 1.45, and mean ratio is 1.33 in post necrotic liver cirrhosis. Ratio is greater than 1.17 in viral cirrhosis, greater than 2.0 in alcoholic hepatitis, and 0.9 in non-alcoholic hepatitis. Ratio is greater than 4.5 in Wilson disease or hyperthyroidism. [6]
A high gradient (> 1.1 g/dL, >11 g/L) indicates the ascites is due to portal hypertension, either liver related or non-liver related, with approximately 97% accuracy. [2] This is due to increased hydrostatic pressure within the blood vessels of the hepatic portal system , which in turn forces water into the peritoneal cavity but leaves proteins ...
Outside the United States, blood tests made up of the majority of the same biochemical tests are called urea and electrolytes (U&E or "U and Es"), or urea, electrolytes, creatinine (UEC or EUC or CUE), and are often referred to as 'kidney function tests' as they also include a calculated estimated glomerular filtration rate. The BMP provides ...
When this happens the numerator is large, the denominator is small, and the result is a delta ratio which is high (>2). This means a combined high anion gap metabolic acidosis and a pre-existing either respiratory acidosis or metabolic alkalosis (causing the high bicarbonate) – i.e. a mixed acid–base metabolic acidosis. [citation needed]
A clinical chemistry analyzer; hand shows size. Clinical chemistry (also known as chemical pathology, clinical biochemistry or medical biochemistry) is a division in medical laboratory sciences focusing on qualitative tests of important compounds, referred to as analytes or markers, in bodily fluids and tissues using analytical techniques and specialized instruments. [1]