enow.com Web Search

  1. Ads

    related to: how to replace boiler drain valve 3 4 to 1 2 pvc reducer

Search results

  1. Results from the WOW.Com Content Network
  2. Piping and plumbing fitting - Wikipedia

    en.wikipedia.org/wiki/Piping_and_plumbing_fitting

    Valves stop (or regulate) the flow of liquids or gases. They are categorized by application, such as isolation, throttling, and non-return. Isolation valves temporarily disconnect part of a piping system to allow maintenance or repair, for example. Isolation valves are typically left in either a fully open or closed position.

  3. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  4. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    A recent introduction to the UK has been the Reduced Pressure Zone (RPZ) valve, a form of double check valve where the intervening zone is drained and normally kept empty. [1] If the downstream valve leaks and permits backflow, this will drain out through the vent rather than building up pressure against the upstream valve.

  5. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices, [1] [2] reduced pressure zone assemblies (RPZA), [3] or reduced pressure principle ...

  6. Isolation valve - Wikipedia

    en.wikipedia.org/wiki/Isolation_valve

    An isolation valve is a valve in a fluid handling system that stops the flow of process media to a given location, usually for maintenance or safety purposes. [1] They can also be used to provide flow logic (selecting one flow path versus another), and to connect external equipment to a system. [ 2 ]

  7. Block and bleed manifold - Wikipedia

    en.wikipedia.org/wiki/Block_and_bleed_manifold

    Two block valves and a bleed valve are as a unit, or manifold, to be installed for positive isolation. Used for critical process service, DBB valves are for high pressure systems or toxic/hazardous fluid processes. Applications that use DBB valves include instrument drain, chemical injection connection, chemical seal isolation, and gauge isolation.

  1. Ads

    related to: how to replace boiler drain valve 3 4 to 1 2 pvc reducer