A trap primer (or trap seal primer) is a plumbing device or valve that adds water to traps.The water seals in traps are needed to prevent sewer gases from entering buildings, but because this water is exposed to the air, it is subject to evaporation over time in infrequently used floor drains, leading to the release of sewer gas into the environment.
A sewer pipe is normally at neutral air pressure compared to the surrounding atmosphere.When a column of waste water flows through a pipe, it compresses air ahead of it in the system, creating a positive pressure that must be released so it does not push back on the waste stream and downstream traps, slow drainage, and induce potential clogs.
The visible water surface in a toilet is the top of the trap's water seal. Each fixture drain, with exceptions, must be vented so that negative air pressure in the drain cannot siphon the trap dry, to prevent positive air pressure in the sewer from forcing gases past the water seal, and to prevent explosive sewer gas buildup.
Trap with copper drain pipe at underside of firestop packing in two-hour fire-resistance rated concrete floor slab Typical P-trap. Maintaining the water seal is critical to trap operation; traps might dry out, and poor venting can suction or blow water out of the traps. This is usually avoided by venting the drain pipes downstream of the trap ...
Pool drain vortex as viewed from above the water at Grange Park wading pool Underwater view of drain, showing vortex-formation phenomenon. A drain is the primary vessel or conduit for unwanted water or waste liquids to flow away, either to a more useful area, funnelled into a receptacle, or run into sewers or stormwater mains as waste discharge to be released or processed.
Floor drain system in bathroom, Korea. A floor drain is a plumbing fixture that is installed in the floor of a structure, mainly designed to remove any standing water near it. They are usually round, but can also be square or rectangular. They usually range from 2 to 12 inches (5.1 to 30.5 cm); most are 4 inches (10 cm) in diameter.
Because certain combinations of check valve failure and/or system backpressure cause the relief valve to discharge, the device must be mounted in a location where the drain will not become flooded. An example of where backflow would harm the water supply is the use of well washing devices inside underground sewerage pumping stations.
The valve must always be installed vertically, usually at the top of a short vertical pipe. If the valve body is filled with water, the float moves upwards and closes the valve. If air collects in the valve body, the waterline lowers, as does the float, and the valve opens to release it. [4]