Search results
Results from the WOW.Com Content Network
The Hammond clock model "Como" The Hammond Clock Company was founded in 1928 to produce and market clocks that were equipped with Hammond's new motor. The Hammond clock factory manufactured more than 100 different clock models, some simple and cheap, others made from expensive materials such as marble and onyx. [4]
The Hammond organ is an electric organ, invented by Laurens Hammond and John M. Hanert [1] and first manufactured in 1935. [2] Various models were produced, which originally used tonewheels to generate sound via additive synthesis , where component waveform ratios are mixed by sliding switches called drawbars and imitate the pipe organ's registers.
Parallel operations: All the transformers should have same phase rotation, vector group, tap setting & polarity of the winding. Ground fault Relay: A Dd transformer does not have neutral. To restrict the ground faults in such systems, we may use a zigzag wound transformer to create a neutral along with the ground fault relay.
For example, a 24 VCT transformer will measure 24 VAC across the outer two taps (winding as a whole), and 12 VAC from each outer tap to the center-tap (half winding). These two 12 VAC supplies are 180 degrees out of phase with each other, measured with respect to the tap, thus making it easy to derive positive and negative 12 volt DC power ...
These markings may be found on transformer cases beside terminals, winding leads, nameplates, schematic and wiring diagrams. The convention is that current entering a transformer at the end of a winding marked with a dot, will tend to produce current exiting other windings at their dotted ends. [citation needed]
Simplified diagram of how a tonewheel works Goldschmidt tone wheel (1910), used as an early beat frequency oscillator. A tonewheel or tone wheel is a simple electromechanical apparatus used for generating electric musical notes in electromechanical organ instruments such as the Hammond organ and in telephony to generate audible signals such as ringing tone.
A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram
Phasor diagram showing 240 V delta and center-tapped phase (a–c) creating two 120 V pairs. Consider the low-voltage side of a 120/240 V high leg delta connected transformer, where the b phase is the high leg.