enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    The disconnecting circuit breaker (DCB) was introduced in 2000 [18] and is a high-voltage circuit breaker modeled after the SF 6-breaker. It presents a technical solution where the disconnecting function is integrated in the breaking chamber, eliminating the need for separate disconnectors.

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.

  4. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Controls for the reclosers range from the original electromechanical systems to digital electronics with metering and SCADA functions. The ratings of reclosers run from 2.4–38 kV for load currents from 10–1200 A and fault currents from 1–16 kA. [7] [8] On a 3-phase circuit, a recloser is more beneficial than three separate fuse cutouts.

  5. Transient recovery voltage - Wikipedia

    en.wikipedia.org/wiki/Transient_Recovery_Voltage

    Examples of TRV waveshapes. A transient recovery voltage (TRV) for high-voltage circuit breakers is the voltage that appears across the terminals after current interruption. It is a critical parameter for fault interruption by a high-voltage circuit breaker, its characteristics (amplitude, rate of rise) can lead either to a successful current interruption or to a failure (called reignition or ...

  6. Transient response - Wikipedia

    en.wikipedia.org/wiki/Transient_response

    The impulse response and step response are transient responses to a specific input (an impulse and a step, respectively). In electrical engineering specifically, the transient response is the circuit’s temporary response that will die out with time. [1]

  7. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Time overcurrent protection operates based on a current vs time curve. Based on this curve, if the measured current exceeds a given level for the preset amount of time, the circuit breaker or fuse will operate. The function of both types is explained in on YouTube.

  8. Settling time - Wikipedia

    en.wikipedia.org/wiki/Settling_time

    The settling time for a second order, underdamped system responding to a step response can be approximated if the damping ratio by = ⁡ () A general form is T s = − ln ⁡ ( tolerance fraction × 1 − ζ 2 ) damping ratio × natural freq {\displaystyle T_{s}=-{\frac {\ln({\text{tolerance fraction}}\times {\sqrt {1-\zeta ^{2}}})}{{\text ...

  9. Hall effect sensor - Wikipedia

    en.wikipedia.org/wiki/Hall_effect_sensor

    Hall effect current sensor with internal integrated circuit amplifier. 8 mm opening. Zero current output voltage is midway between the supply voltages that maintain a 4 to 8-volt differential. The non-zero current response is proportional to the voltage supplied and is linear to 60 amperes for this particular (25 A) device.