enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. X-ray image intensifier - Wikipedia

    en.wikipedia.org/wiki/X-ray_image_intensifier

    A system containing an image intensifier may be used either as a fixed piece of equipment in a dedicated screening room or as mobile equipment for use in an operating theatre. A mobile fluoroscopy unit generally consists of two units, the X-ray generator and image detector (II) on a moveable C-arm, and a separate workstation unit used to store ...

  3. Image intensifier - Wikipedia

    en.wikipedia.org/wiki/Image_intensifier

    An image intensifier or image intensifier tube is a vacuum tube device for increasing the intensity of available light in an optical system to allow use under low-light conditions, such as at night, to facilitate visual imaging of low-light processes, such as fluorescence of materials in X-rays or gamma rays (X-ray image intensifier), or for conversion of non-visible light sources, such as ...

  4. Fluoroscopy - Wikipedia

    en.wikipedia.org/wiki/Fluoroscopy

    Contrast ratio is also improved over image intensifiers; flat-panel detectors are linear over a very wide latitude, whereas image intensifiers have a maximum contrast ratio of about 35:1. Spatial resolution is roughly equal, although an image intensifier operating in magnification mode may be slightly better than a flat panel.

  5. G-arm medical imaging - Wikipedia

    en.wikipedia.org/wiki/G-arm_medical_imaging

    G-arm medical imaging systems are based on fluoroscopic X-ray and are used for a variety of diagnostic imaging and minimally invasive surgical procedures.The name is derived from the G-shaped arm used to connect two X-ray generators and two X-ray detectors, image intensifiers or digital flat panel detectors, to one another.

  6. Flat-panel detector - Wikipedia

    en.wikipedia.org/wiki/Flat-panel_detector

    For fluoroscopy, they are lighter, far more durable, smaller in volume, more accurate, and have much less image distortion than x-ray image intensifiers and can also be produced with larger areas. [7] Disadvantages compared to IIs can include defective image elements, higher costs and lower spatial resolution. [8]

  7. Radiography - Wikipedia

    en.wikipedia.org/wiki/Radiography

    The last can often be carried out in the operating theatre, using a portable fluoroscopy machine called a C-arm. [11] It can move around the surgery table and make digital images for the surgeon. Biplanar Fluoroscopy works the same as single plane fluoroscopy except displaying two planes at the same time.

  8. Fluorescence imaging - Wikipedia

    en.wikipedia.org/wiki/Fluorescence_imaging

    Images can be produced from a variety of methods including: microscopy, imaging probes, and spectroscopy. Fluorescence itself, is a form of luminescence that results from matter emitting light of a certain wavelength after absorbing electromagnetic radiation. Molecules that re-emit light upon absorption of light are called fluorophores. [1] [2]

  9. Photostimulated luminescence - Wikipedia

    en.wikipedia.org/wiki/Photostimulated_luminescence

    A plate based on this mechanism is called a photostimulable phosphor (PSP) plate (or imaging plate) and is one type of X-ray detector used in projectional radiography. Creating an image requires illuminating the plate twice: the first exposure, to the radiation of interest, "writes" the image, and a later, second illumination (typically by a ...