enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. X-ray image intensifier - Wikipedia

    en.wikipedia.org/wiki/X-ray_image_intensifier

    A system containing an image intensifier may be used either as a fixed piece of equipment in a dedicated screening room or as mobile equipment for use in an operating theatre. A mobile fluoroscopy unit generally consists of two units, the X-ray generator and image detector (II) on a moveable C-arm, and a separate workstation unit used to store ...

  3. Image intensifier - Wikipedia

    en.wikipedia.org/wiki/Image_intensifier

    An image intensifier or image intensifier tube is a vacuum tube device for increasing the intensity of available light in an optical system to allow use under low-light conditions, such as at night, to facilitate visual imaging of low-light processes, such as fluorescence of materials in X-rays or gamma rays (X-ray image intensifier), or for conversion of non-visible light sources, such as ...

  4. Fluoroscopy - Wikipedia

    en.wikipedia.org/wiki/Fluoroscopy

    Contrast ratio is also improved over image intensifiers; flat-panel detectors are linear over a very wide latitude, whereas image intensifiers have a maximum contrast ratio of about 35:1. Spatial resolution is roughly equal, although an image intensifier operating in magnification mode may be slightly better than a flat panel.

  5. Radiography - Wikipedia

    en.wikipedia.org/wiki/Radiography

    The last can often be carried out in the operating theatre, using a portable fluoroscopy machine called a C-arm. [11] It can move around the surgery table and make digital images for the surgeon. Biplanar Fluoroscopy works the same as single plane fluoroscopy except displaying two planes at the same time.

  6. Flat-panel detector - Wikipedia

    en.wikipedia.org/wiki/Flat-panel_detector

    For fluoroscopy, they are lighter, far more durable, smaller in volume, more accurate, and have much less image distortion than x-ray image intensifiers and can also be produced with larger areas. [7] Disadvantages compared to IIs can include defective image elements, higher costs and lower spatial resolution. [8]

  7. Photostimulated luminescence - Wikipedia

    en.wikipedia.org/wiki/Photostimulated_luminescence

    A plate based on this mechanism is called a photostimulable phosphor (PSP) plate (or imaging plate) and is one type of X-ray detector used in projectional radiography. Creating an image requires illuminating the plate twice: the first exposure, to the radiation of interest, "writes" the image, and a later, second illumination (typically by a ...

  8. Charge-coupled device - Wikipedia

    en.wikipedia.org/wiki/Charge-coupled_device

    An intensified charge-coupled device (ICCD) is a CCD that is optically connected to an image intensifier that is mounted in front of the CCD. An image intensifier includes three functional elements: a photocathode, a micro-channel plate (MCP) and a phosphor screen. These three elements are mounted one close behind the other in the mentioned ...

  9. Fluorescence-lifetime imaging microscopy - Wikipedia

    en.wikipedia.org/wiki/Fluorescence-lifetime...

    The fluorescence lifetime (FLT) of the fluorophore, rather than its intensity, is used to create the image in FLIM. Fluorescence lifetime depends on the local micro-environment of the fluorophore, thus precluding any erroneous measurements in fluorescence intensity due to change in brightness of the light source, background light intensity or ...