enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Uninterruptible power supply - Wikipedia

    en.wikipedia.org/wiki/Uninterruptible_power_supply

    A large data-center-scale UPS being installed by electricians. An uninterruptible power supply (UPS) or uninterruptible power source is a type of continual power system that provides automated backup electric power to a load when the input power source or mains power fails.

  3. Diesel rotary uninterruptible power supply - Wikipedia

    en.wikipedia.org/wiki/Diesel_rotary...

    Most forms of uninterruptible power supply (UPS) can be either powered by battery or flywheel energy. These are ready for immediate use at the instant that the mains electricity fails, but the relatively small and finite amount of stored energy they contain makes them suitable for short periods of use, typically in the order of a few dozen minutes to a couple of hours depending on the actual load.

  4. Capacity factor - Wikipedia

    en.wikipedia.org/wiki/Capacity_factor

    Many other power plants operate only at certain times of the day or year because of variation in loads and electricity prices. If a plant is only needed during the day, for example, even if it operates at full power output from 8 am to 8 pm every day (12 hours) all year long, it would only have a 50% capacity factor.

  5. List of largest power stations - Wikipedia

    en.wikipedia.org/wiki/List_of_largest_power_stations

    As of 2019, no power station comparable to Three Gorges is under construction, as the largest under construction power station is the hydroelectric Baihetan Dam (16,000 MW). [ 2 ] The proposed 20,000 MW Australia 's Darwin Solar Park , for the Australia-Asia Power Link , would be slightly below the capacity of the Three Gorges Dam.

  6. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    At low values of power factor, more apparent power needs to be transferred to get the same real power. To get 1 kW of real power at 0.2 power factor, 5 kVA of apparent power needs to be transferred (1 kW ÷ 0.2 = 5 kVA). This apparent power must be produced and transmitted to the load and is subject to losses in the production and transmission ...

  7. Availability factor - Wikipedia

    en.wikipedia.org/wiki/Availability_factor

    The difference arises when the plant is run at less than full capacity, in which case the capacity factor is less than the availability factor. The availability of a power plant varies greatly depending on the type of fuel, the design of the plant and how the plant is operated. Everything else being equal, plants that are run less frequently ...

  8. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  9. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    A common prefixed derived unit is "kilovolt-ampere" (symbol kVA). The VA rating is limited by the maximum permissible current, and the watt rating by the power-handling capacity of the device. When a UPS powers equipment which presents a reactive load with a low power factor, neither limit may safely be exceeded. [4]