enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    Circuit diagram for open-circuit test. The open-circuit test, or no-load test, is one of the methods used in electrical engineering to determine the no-load impedance in the excitation branch of a transformer. The no load is represented by the open circuit, which is represented on the right side of the figure as the "hole" or incomplete part of ...

  3. IEC 61000-4-5 - Wikipedia

    en.wikipedia.org/wiki/IEC_61000-4-5

    The surge is defined by the Combination Wave Generator's open-circuit voltage and short-circuit current waveforms, characterized by front time, duration, and peak values. With an open circuit output, the surge voltage is a double exponential pulse in the form of k ( e − α t − e − β t ) {\displaystyle k(e^{-\alpha t}-e^{-\beta t})} .

  4. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.

  5. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found.

  6. Open-circuit time constant method - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_time_constant...

    Select capacitor C 1, replace it by a test voltage V X, and replace C 2 by an open circuit. Then the resistance seen by the test voltage is found using the circuit in the right panel of Figure 1 and is simply V X / I X = R 1. Form the product C 1 R 1. Add these terms. In effect, it is as though each capacitor charges and discharges through the ...

  7. Time-domain reflectometer - Wikipedia

    en.wikipedia.org/wiki/Time-domain_reflectometer

    It is only after this round-trip delay that the short can be detected by the TDR. With knowledge of the signal propagation speed in the particular cable-under-test, the distance to the short can be measured. A similar effect occurs if the far end of the cable is an open circuit (terminated into an infinite impedance).

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Open-circuit saturation curve - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_saturation_curve

    The open-circuit saturation curve (also open-circuit characteristic, OCC) of a synchronous generator is a plot of the output open circuit voltage as a function of the excitation current or field. The curve is typically plotted alongside the synchronous impedance curve .