enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    In an alternating current (AC) electric power system, synchronization is the process of matching the frequency, phase and voltage of a generator or other source to an electrical grid in order to transfer power. If two unconnected segments of a grid are to be connected to each other, they cannot safely exchange AC power until they are synchronized.

  3. Electrical grid - Wikipedia

    en.wikipedia.org/wiki/Electrical_grid

    This allows transmission of AC power throughout the area, connecting the electricity generators with consumers. Grids can enable more efficient electricity markets. Although electrical grids are widespread, as of 2016, 1.4 billion people worldwide were not connected to an electricity grid. [1]

  4. Electric power system - Wikipedia

    en.wikipedia.org/wiki/Electric_power_system

    Electricity grid systems connect multiple generators operating at the same frequency: the most common being three-phase at 50 or 60 Hz. There are a range of design considerations for power supplies. These range from the obvious: How much power should the generator be able to supply?

  5. Droop speed control - Wikipedia

    en.wikipedia.org/wiki/Droop_speed_control

    Droop speed control is a control mode used for AC electrical power generators, whereby the power output of a generator reduces as the line frequency increases. It is commonly used as the speed control mode of the governor of a prime mover driving a synchronous generator connected to an electrical grid. It works by controlling the rate of power ...

  6. Generator interlock kit - Wikipedia

    en.wikipedia.org/wiki/Generator_Interlock_Kit

    Without a UL Listing, some electrical inspectors will not allow the use of these interlock kits. With kits installed on the electrical panel's cover, removing the cover could allow the generator backfeed breaker to be turned on while the main is on, [4] potentially energizing power lines or overloading the generator, if the generator is connected.

  7. Inverter-based resource - Wikipedia

    en.wikipedia.org/wiki/Inverter-based_resource

    An inverter-based resource (IBR) is a source of electricity that is asynchronously connected to the electrical grid via an electronic power converter ("inverter"). The devices in this category, also known as converter interfaced generation (CIG), include the variable renewable energy generators (wind, solar) and battery storage power stations. [1]

  8. Grid-tie inverter - Wikipedia

    en.wikipedia.org/wiki/Grid-tie_inverter

    A grid-tie inverter converts direct current (DC) into an alternating current (AC) suitable for injecting into an electrical power grid, at the same voltage and frequency of that power grid. Grid-tie inverters are used between local electrical power generators: solar panel, wind turbine, hydro-electric, and the grid. [1]

  9. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    The term grid strength (also system strength) is used to describe the resiliency of the grid to the small changes in the vicinity of the grid location (“grid stiffness”). [5] From the side of an electrical generator, the system strength is related to the changes of voltage the generator encounters on its terminals as the generator's current ...