enow.com Web Search

  1. Ad

    related to: vertical fire pump piping layout

Search results

  1. Results from the WOW.Com Content Network
  2. Standpipe (firefighting) - Wikipedia

    en.wikipedia.org/wiki/Standpipe_(firefighting)

    External access point for fire sprinkler and dry standpipe at a building in San Francisco, US Antique wet standpipe preserved at Edison and Ford Winter Estates. A standpipe or riser is a type of rigid water piping which is built into multi-story buildings in a vertical position, or into bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water ...

  3. Fire pump - Wikipedia

    en.wikipedia.org/wiki/Fire_pump

    A jockey pump, also known as a pressure-maintenance pump, is a small pump connected to a fire suppression system near the fire pump and is intended to maintain pressure in a fire protection piping system. These pumps recover pressures lost from gradual, slow pressure declines in a system due to temperature changes, trapped air escapement, or ...

  4. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    Hydraulic calculations verify that the water flowrate (or water mixed with additives like firefighting foam concentrate) through piping networks for the purpose of suppressing or extinguishing a fire will be sufficient to meet design objectives.

  5. Riser clamp - Wikipedia

    en.wikipedia.org/wiki/Riser_clamp

    The copper pipe penetration is firestopped with firestop mortar. Riser clamp for a standpipe through-penetration firestop inside a fire hose cabinet under construction. A riser clamp is a type of hardware used by mechanical building trades for pipe support in vertical runs of piping (risers) at each floor level. The devices are placed around ...

  6. Flow distribution in manifolds - Wikipedia

    en.wikipedia.org/wiki/Flow_distribution_in_manifolds

    Thus the flow rate of the straight pipe is greater than that of the vertical one. Furthermore, because the lower energy fluid in the boundary layer branches through the channels the higher energy fluid in the pipe centre remains in the pipe as shown in Fig. 4. Fig. 4. Velocity profile along a manifold

  7. Gooseneck (piping) - Wikipedia

    en.wikipedia.org/wiki/Gooseneck_(piping)

    Gooseneck vent with check valve being repainted. A gooseneck (or goose neck) is a 180° pipe fitting at the top of a vertical pipe that prevents entry of water. Common implementations of goosenecks are ventilator piping or ducting for bathroom and kitchen exhaust fans, ship holds, landfill methane vent pipes, or any other piping implementation exposed to the weather where water ingress would ...

  8. Net positive suction head - Wikipedia

    en.wikipedia.org/wiki/Net_positive_suction_head

    Example Number 3: A well or bore running at 70 degrees Celsius (158F) with an operating level of 5 metres below the intake, minus a 2 metre friction loss into pump (pipe loss), minus the NPSH R curve (say 2.4 metres) of the pre-designed pump, minus a temperature loss of 3 metres/10 feet = an NPSH A (available) of (negative) -12.4 metres.

  9. Pumping station - Wikipedia

    en.wikipedia.org/wiki/Pumping_station

    Submersible pumps are mounted on two vertical guide rails and seal onto a permanently fixed "duckfoot", which forms both a mount and also a vertical bend for the discharge pipe. For maintenance or replacement, submersible pumps are raised by a chain off of the duckfoot and up the two guide rails to the maintenance (normally ground) level.

  1. Ad

    related to: vertical fire pump piping layout