  1. Results from the WOW.Com Content Network
  2. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    The following are nominal current ratings for copper conductors; long runs may require thicker wires to minimize voltage drop. White: 14 AWG wire (2.08 mm 2) for 15-amp circuits Yellow: 12 AWG wire (3.31 mm 2) for 20-amp circuits Orange: 10 AWG wire (5.26 mm 2) for 30-amp circuits

  3. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V or 120v. Countries such as Mexico may adopt the NFPA standard as their national electrical code, with local amendments similar to those in United States jurisdictions.

  4. Knob-and-tube wiring - Wikipedia

    en.wikipedia.org/wiki/Knob-and-tube_wiring

    The conduit methods were known to be of better quality, but cost significantly more than K&T. [2] In 1909, flexible armored cable cost about twice as much as K&T, and conduit cost about three times the price of K&T. [6] Knob and tube wiring persisted since it allowed owners to wire a building for electricity at lower cost.

  5. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission .

  6. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    A lower rating will apply if multiple conductors are in proximity, since each contributes heat to the others and diminishes the amount of external cooling of the conductors. Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75, and 90 °C, often with an ambient air ...

  7. Twin and earth - Wikipedia

    en.wikipedia.org/wiki/Twin_and_earth

    'Twin and Earth' electrical cable to British Standard 6004, with twin 6 mm² conductors and uninsulated 2.5 mm² earth continuity conductor. Twin and earth (often written "T&E" and sometimes "T and E") cable is a colloquial name in the UK, Australia, New Zealand and other countries for a type of flat sheathed fixed mains electricity cable, containing two insulated current-carrying conductors ...

  8. NEMA size - Wikipedia

    en.wikipedia.org/wiki/NEMA_size

    6: 540: 150: 200: 400 7: 810-300: 600 8: 1215-450: 900 9: 2250-800: 1600 See also. Contactor; Motor starter; References This page was last edited on 20 June 2020, at ...

  9. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Accordingly, one pound of aluminum has the same current carrying capacity as two pounds of copper. [3] Since copper costs about four times as much as aluminum by weight (roughly US$4 /lb [ 5 ] vs. US$1 /lb [ 6 ] as of 2024 [update] ), aluminum wires are one-eighth the cost of copper wire of the same conductivity.