Ad
related to: rough idle and misfire power plant system- 969 E Main St, Columbus, OH · Directions · (614) 257-0248
Search results
Results from the WOW.Com Content Network
Combined cycle power plants use the high temperature exhaust to boil and superheat water steam to run a steam turbine. Thus, the efficiency is higher because more energy is extracted from the fuel than what could be extracted by the combustion engine alone. Combined cycle power plants achieve efficiencies in the range of 50–60%.
A process plant shutdown system is a functional safety countermeasure crucial in any hazardous process plant such as oil and gas production plants and oil refineries. The concept also applies to non-process facilities such as nuclear plants. These systems are used to protect people, assets, and the environment when process conditions get out of ...
Idle speed, sometimes simply called "idle", is the rotational speed an engine runs at when the engine is idling, that is when the engine is uncoupled from the drivetrain and the throttle pedal is not depressed. In combustion engines, idle speed is generally measured in revolutions per minute (rpm) of the crankshaft.
Pressure in cylinder pattern in dependence on ignition timing: (a) - misfire, (b) too soon, (c) optimal, (d) too late. In a spark ignition internal combustion engine, ignition timing is the timing, relative to the current piston position and crankshaft angle, of the release of a spark in the combustion chamber near the end of the compression stroke.
In spark-ignition internal combustion engines, knocking (also knock, detonation, spark knock, pinging or pinking) occurs when combustion of some of the air/fuel mixture in the cylinder does not result from propagation of the flame front ignited by the spark plug, but when one or more pockets of air/fuel mixture explode outside the envelope of the normal combustion front.
The Cummins M-series engine is a straight-six diesel engine designed and produced by Cummins.It displaces 10.8 litres (659.1 cu in).Introduced as the M11 in 1994, it was built on the previous L10 engine (same 4.921 inches (125.0 mm) cylinder bore, but a longer 5.787 inches (147.0 mm) piston stroke compared to the L10's 5.354 inches (136.0 mm) stroke).
The Auris then had all of its power plants replaced with a 3,910 kW (5,250 shp) directly coupled gas turbine to become the first civilian ship to operate solely on gas turbine power. Despite the success of this early experimental voyage the gas turbine did not replace the diesel engine as the propulsion plant for large merchant ships.
Forced outage rate (FOR or FOAR) of a power station unit is the probability that the unit will not be available for service when required.. FOR is defined as the number of hours the unit is on forced outage over the total number of hours in a year (which is the sum of hours the power station is available for service and hours the power station is in forced outage).
Ad
related to: rough idle and misfire power plant system- 969 E Main St, Columbus, OH · Directions · (614) 257-0248