enow.com Web Search

  1. Ads

    related to: cost of radiant floor heating per square foot abbreviation calculator

Search results

  1. Results from the WOW.Com Content Network
  2. Equivalence of direct radiation - Wikipedia

    en.wikipedia.org/wiki/Equivalence_of_direct...

    Equivalence of direct radiation (EDR) is a standardized comparison method for estimating the output ability of space-heating radiators and convectors. Measured in square feet, the reference standard for EDR is the mattress radiator [ 1 ] invented by Stephen J. Gold in the mid 19th century.

  3. Underfloor heating - Wikipedia

    en.wikipedia.org/wiki/Underfloor_heating

    A.M. Byers of America promotes radiant heating using small bore water pipes. Asia continues to use traditional ondol and kang—wood is used as the fuel, combustion gases sent under floor. 1930: Oscar Faber in England uses water pipes used to radiant heat and cool several large buildings. [15] 1933

  4. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    The whole floor is evenly heated. Thus, the room is heated from the bottom up. Radiant floor heating eliminates the draft and dust problems associated with forced air heating systems. radiation The transfer of heat directly from one surface to another (without heating the intermediate air acting as a transfer mechanism). SEER

  5. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)

  6. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLF is the cooling load at a given time compared to the heat gain from earlier in the day. [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load.

  7. Gypsum concrete - Wikipedia

    en.wikipedia.org/wiki/Gypsum_concrete

    Gypsum concrete is lightweight and fire-resistant. A 1.5-inch slab of gypsum concrete weighs 13 pounds per square foot versus 18 pounds per square foot for regular concrete. [10] Even though gypsum concrete weighs less, it still has the same compressive strength as regular concrete, based on its application as underlayment or top coat flooring ...

  8. Heating film - Wikipedia

    en.wikipedia.org/wiki/Heating_film

    Heating films are lightweight, typically 200 to 300 grams per square metre (0.061 lb/sq ft). Greenhouse gas emissions due to shipping will depend on distance travelled and transport method. Assuming the heating film travels a similar distance to other heating systems from manufacturer to installation, due to its comparatively low weight ...

  9. British thermal unit - Wikipedia

    en.wikipedia.org/wiki/British_thermal_unit

    The SI unit of power for heating and cooling systems is the watt. Btu per hour (Btu/h) is sometimes used in North America and the United Kingdom - the latter for air conditioning mainly, though "Btu/h" is sometimes abbreviated to just "Btu". [18] MBH—thousands of Btu per hour—is also common. [19] 1 W is approximately 3.412142 Btu/h [20]

  1. Ads

    related to: cost of radiant floor heating per square foot abbreviation calculator